BTI-7000-MIB :: amdHistPMOPRValue

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsBTI-7000-MIBamdHistPMOPRValue

amdHistPMOPRValue

Module: BTI-7000-MIB

OID (symbolic): BTI-7000-MIB::amdHistPMOPRValue

OID (numeric): 1.3.6.1.4.1.18070.2.2.1.6.7.1.8

Node type: OBJECT-TYPE

Type: FixedX10

Access: read-only

Description: The optical power received on the input of the AMD port.

What is amdHistPMOPRValue?

Reports a historical optical receive power measurement captured at the AMD port's input during a previous performance monitoring interval. This historical value enables trend analysis and comparison against current readings to detect degradation over time.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.18070.2.2.1.6.7.1.8
snmpwalk -v2c -c public <target> BTI-7000-MIB::amdHistPMOPRValue

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.18070.2.2.1.6.7.1.8.1
snmpget -v2c -c public <target> BTI-7000-MIB::amdHistPMOPRValue.1

Start monitoring BTI Systems optical transport devices with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BTI-7000-MIB::amdHistPMOPRValue OID value, configure state conditions and alerts, and monitor any BTI Systems optical transport devices from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.18070btiSystemsBTI-MIB
1.3.6.1.4.1.18070.2btiProductsBTI-MIB
1.3.6.1.4.1.18070.2.2bti7000BTI-MIB
Numeric OIDNameModule
1.3.6.1.4.1.18070.2.2.1objectsBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.1.6performanceBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.1.6.7amdHistPMTableBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.1.6.7.1amdHistPMEntryBTI-7000-MIB
1.3.6.1.4.1.18070.2.2.1.6.7.1.8amdHistPMOPRValueBTI-7000-MIB