BROCADE-MCT-CLUSTER-MIB :: brcdMctClusterDeployFailureReason

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › BROCADE-MCT-CLUSTER-MIB › brcdMctClusterDeployFailureReason

brcdMctClusterDeployFailureReason

Module: BROCADE-MCT-CLUSTER-MIB

OID (symbolic): BROCADE-MCT-CLUSTER-MIB::brcdMctClusterDeployFailureReason

OID (numeric): 1.3.6.1.4.1.1991.1.1.12.1.1.2.1.11

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The last failure reason for cluster deploy operation through SNMP. The following failure reason codes are supported: none(1) - The last deploy is successful. unknown(2) - The last deploy has failed for unknown reason. rBridgeIdNotConfigured(3) - Remote bridge id is not configured. sessionVlanNotConfigured(4) - Session VLAN is not configured. iclNotConfigured(5) - ICL is not configured. peerNotConfigured(6) - Peer is not configured. iclIsMrpSecondaryInterface(7) - In NI CES/CER devices, ICL should not be MRP secondary interface. iclIsErpRplInterface(8) - In NI CES/CER devices, ICL should not be ERP RPL interface. iclIsErpMsInterface(9) - In NI CES/CER devices, ICL should not be ERP MS interface. iclIsErpFsInterface(10) - In NI CES/CER devices, ICL should not be ERP FS interface. iclNotInSessionVlan(11) - ICL is not in session VLAN. iclNotInMemberVlans(12) - ICL is not in member VLANs. nonIclInterfacesInSessionVlan(13) - Non ICL interfaces are present under session VLAN. mgmtVeNotConfiguredInSessionVlan(14) - Management VE is not configured in session VLAN. mgmtIpNotConfiguredInSessionVlan(15) - Management IP is not configured in session VLAN. mgmtIpIsUsedInPeerOrClientConfig(16) - Management IP is used in peer or client configuration. mgmtIpNotInSubnetOfPeerIp(17) - Management IP is not in subnet of peer IP. rBridgeIdUsedInPeerOrClientConfig(18) - Remote bridge id is used in peer or client configuration. clientInterfaceIsNotInMemberVlan(19) - Client interface is not in member VLAN. defaultVlanConfigAsSessOrMemberVlan(20) - Default VLAN is configured as session or member VLAN.

What is brcdMctClusterDeployFailureReason?

Reports the reason code explaining why the most recent SNMP-initiated cluster deploy operation failed. A value of none(1) indicates the last deploy was successful.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1991.1.1.12.1.1.2.1.11
snmpwalk -v2c -c public <target> BROCADE-MCT-CLUSTER-MIB::brcdMctClusterDeployFailureReason

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1991.1.1.12.1.1.2.1.11.1
snmpget -v2c -c public <target> BROCADE-MCT-CLUSTER-MIB::brcdMctClusterDeployFailureReason.1

Start monitoring Brocade NetIron XMR/MLX CES/CER chassis routers and switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BROCADE-MCT-CLUSTER-MIB::brcdMctClusterDeployFailureReason OID value, configure state conditions and alerts, and monitor any Brocade NetIron XMR/MLX CES/CER chassis routers and switches from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1991foundryFOUNDRY-SN-ROOT-MIB
1.3.6.1.4.1.1991.1productsFOUNDRY-SN-ROOT-MIB
1.3.6.1.4.1.1991.1.1switchFOUNDRY-SN-ROOT-MIB
1.3.6.1.4.1.1991.1.1.12brcdMctFOUNDRY-SN-ROOT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1991.1.1.12.1brcdMctMIBBROCADE-MCT-CLUSTER-MIB
1.3.6.1.4.1.1991.1.1.12.1.1brcdMctObjectsBROCADE-MCT-CLUSTER-MIB
1.3.6.1.4.1.1991.1.1.12.1.1.2brcdMctClusterTableBROCADE-MCT-CLUSTER-MIB
1.3.6.1.4.1.1991.1.1.12.1.1.2.1brcdMctClusterEntryBROCADE-MCT-CLUSTER-MIB
1.3.6.1.4.1.1991.1.1.12.1.1.2.1.11brcdMctClusterDeployFailureReasonBROCADE-MCT-CLUSTER-MIB