All MIBs › BLADETYPE6-NETWORK-MIB › radNewCfgBackdoor
radNewCfgBackdoor
Module: BLADETYPE6-NETWORK-MIB
OID (symbolic): BLADETYPE6-NETWORK-MIB::radNewCfgBackdoor
OID (numeric): 1.3.6.1.4.1.11.2.3.7.11.33.6.2.1.1.3.16
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Enable or disable RADIUS backdoor for telnet/ssh/http/https.
What is radNewCfgBackdoor?
This writable OID enables or disables the RADIUS backdoor login for Telnet, SSH, HTTP, and HTTPS management access. The backdoor allows local authentication to succeed even when the RADIUS server cannot be reached.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.3.7.11.33.6.2.1.1.3.16 snmpwalk -v2c -c public <target> BLADETYPE6-NETWORK-MIB::radNewCfgBackdoor
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.3.7.11.33.6.2.1.1.3.16.1 snmpget -v2c -c public <target> BLADETYPE6-NETWORK-MIB::radNewCfgBackdoor.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.11.2.3.7.11.33.6.2.1.1.3.16.1 i <value>
Start monitoring HP BladeSystem Type 6 / ProLiant GbE2c 10G Interconnect Switch with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BLADETYPE6-NETWORK-MIB::radNewCfgBackdoor OID value, configure state conditions and alerts, and monitor any HP BladeSystem Type 6 / ProLiant GbE2c 10G Interconnect Switch from a single console.
OID Breakdown
Upper-level ancestors (14 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.11 | hp | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2 | nm | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2.3 | hpsystem | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2.3.7 | netElement | HP-ICF |
| 1.3.6.1.4.1.11.2.3.7.11 | hpEtherSwitch | HP-ICF-OID |
| 1.3.6.1.4.1.11.2.3.7.11.33 | hpSwitchProliant | HP-ICF-OID |
| 1.3.6.1.4.1.11.2.3.7.11.33.6 | hpSwitchModuleBladetype6 | HP-SWITCH-PL-MIB |
| 1.3.6.1.4.1.11.2.3.7.11.33.6.2 | hpSwitchBladeType6_Mgmt | HP-SWITCH-PL-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.11.2.3.7.11.33.6.2.1 | agent | BLADETYPE6-NETWORK-MIB |
| 1.3.6.1.4.1.11.2.3.7.11.33.6.2.1.1 | agentConfig | BLADETYPE6-NETWORK-MIB |
| 1.3.6.1.4.1.11.2.3.7.11.33.6.2.1.1.3 | agRadiusConfig | BLADETYPE6-NETWORK-MIB |
| 1.3.6.1.4.1.11.2.3.7.11.33.6.2.1.1.3.16 | radNewCfgBackdoor | BLADETYPE6-NETWORK-MIB |