BLADETYPE6-NETWORK-MIB :: radCurCfgTimeout

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsBLADETYPE6-NETWORK-MIBradCurCfgTimeout

radCurCfgTimeout

Module: BLADETYPE6-NETWORK-MIB

OID (symbolic): BLADETYPE6-NETWORK-MIB::radCurCfgTimeout

OID (numeric): 1.3.6.1.4.1.11.2.3.7.11.33.6.2.1.1.3.7

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The maximum number of seconds before resending authentication to RADIUS server.

What is radCurCfgTimeout?

This read-only OID reports the current timeout value (in seconds) the switch waits before retransmitting an authentication request to the RADIUS server. It helps identify how long the switch will wait before assuming a RADIUS server is unresponsive.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.3.7.11.33.6.2.1.1.3.7
snmpwalk -v2c -c public <target> BLADETYPE6-NETWORK-MIB::radCurCfgTimeout

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.3.7.11.33.6.2.1.1.3.7.1
snmpget -v2c -c public <target> BLADETYPE6-NETWORK-MIB::radCurCfgTimeout.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> radCurCfgTimeout.1

Start monitoring HP BladeSystem Type 6 / ProLiant GbE2c 10G Interconnect Switch with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BLADETYPE6-NETWORK-MIB::radCurCfgTimeout OID value, configure state conditions and alerts, and monitor any HP BladeSystem Type 6 / ProLiant GbE2c 10G Interconnect Switch from a single console.

OID Breakdown

Upper-level ancestors (14 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.11hpCLJ8500-MIB
1.3.6.1.4.1.11.2nmCLJ8500-MIB
1.3.6.1.4.1.11.2.3hpsystemCLJ8500-MIB
1.3.6.1.4.1.11.2.3.7netElementHP-ICF
1.3.6.1.4.1.11.2.3.7.11hpEtherSwitchHP-ICF-OID
1.3.6.1.4.1.11.2.3.7.11.33hpSwitchProliantHP-ICF-OID
1.3.6.1.4.1.11.2.3.7.11.33.6hpSwitchModuleBladetype6HP-SWITCH-PL-MIB
1.3.6.1.4.1.11.2.3.7.11.33.6.2hpSwitchBladeType6_MgmtHP-SWITCH-PL-MIB
Numeric OIDNameModule
1.3.6.1.4.1.11.2.3.7.11.33.6.2.1agentBLADETYPE6-NETWORK-MIB
1.3.6.1.4.1.11.2.3.7.11.33.6.2.1.1agentConfigBLADETYPE6-NETWORK-MIB
1.3.6.1.4.1.11.2.3.7.11.33.6.2.1.1.3agRadiusConfigBLADETYPE6-NETWORK-MIB
1.3.6.1.4.1.11.2.3.7.11.33.6.2.1.1.3.7radCurCfgTimeoutBLADETYPE6-NETWORK-MIB