BLADETYPE6-NETWORK-MIB :: ospfIfNbrBackupDesignatedRtr

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsBLADETYPE6-NETWORK-MIBospfIfNbrBackupDesignatedRtr

ospfIfNbrBackupDesignatedRtr

Module: BLADETYPE6-NETWORK-MIB

OID (symbolic): BLADETYPE6-NETWORK-MIB::ospfIfNbrBackupDesignatedRtr

OID (numeric): 1.3.6.1.4.1.11.2.3.7.11.33.6.2.3.3.4.5.1.6

Node type: OBJECT-TYPE

Type: IpAddress

Access: read-only

Description: The IP Address of the backup designated Router for this OSPF Neighbor.

What is ospfIfNbrBackupDesignatedRtr?

Reports the IP address of the Backup Designated Router for the network segment shared with this OSPF neighbor. The Backup Designated Router stands ready to take over the Designated Router role if the primary fails.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.3.7.11.33.6.2.3.3.4.5.1.6
snmpwalk -v2c -c public <target> BLADETYPE6-NETWORK-MIB::ospfIfNbrBackupDesignatedRtr

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.3.7.11.33.6.2.3.3.4.5.1.6.1
snmpget -v2c -c public <target> BLADETYPE6-NETWORK-MIB::ospfIfNbrBackupDesignatedRtr.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> ospfIfNbrBackupDesignatedRtr.1

Start monitoring HP BladeSystem Type 6 / ProLiant GbE2c 10G Interconnect Switch with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BLADETYPE6-NETWORK-MIB::ospfIfNbrBackupDesignatedRtr OID value, configure state conditions and alerts, and monitor any HP BladeSystem Type 6 / ProLiant GbE2c 10G Interconnect Switch from a single console.

OID Breakdown

Upper-level ancestors (14 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.11hpCLJ8500-MIB
1.3.6.1.4.1.11.2nmCLJ8500-MIB
1.3.6.1.4.1.11.2.3hpsystemCLJ8500-MIB
1.3.6.1.4.1.11.2.3.7netElementHP-ICF
1.3.6.1.4.1.11.2.3.7.11hpEtherSwitchHP-ICF-OID
1.3.6.1.4.1.11.2.3.7.11.33hpSwitchProliantHP-ICF-OID
1.3.6.1.4.1.11.2.3.7.11.33.6hpSwitchModuleBladetype6HP-SWITCH-PL-MIB
1.3.6.1.4.1.11.2.3.7.11.33.6.2hpSwitchBladeType6_MgmtHP-SWITCH-PL-MIB
Numeric OIDNameModule
1.3.6.1.4.1.11.2.3.7.11.33.6.2.3layer3BLADETYPE6-NETWORK-MIB
1.3.6.1.4.1.11.2.3.7.11.33.6.2.3.3layer3InfoBLADETYPE6-NETWORK-MIB
1.3.6.1.4.1.11.2.3.7.11.33.6.2.3.3.4ospfInfoBLADETYPE6-NETWORK-MIB
1.3.6.1.4.1.11.2.3.7.11.33.6.2.3.3.4.5ospfIfNbrTableBLADETYPE6-NETWORK-MIB
1.3.6.1.4.1.11.2.3.7.11.33.6.2.3.3.4.5.1ospfIfNbrEntryBLADETYPE6-NETWORK-MIB
1.3.6.1.4.1.11.2.3.7.11.33.6.2.3.3.4.5.1.6ospfIfNbrBackupDesignatedRtrBLADETYPE6-NETWORK-MIB