All MIBs › BLADETYPE6-NETWORK-MIB › mstNewCfgRegionName
mstNewCfgRegionName
Module: BLADETYPE6-NETWORK-MIB
OID (symbolic): BLADETYPE6-NETWORK-MIB::mstNewCfgRegionName
OID (numeric): 1.3.6.1.4.1.11.2.3.7.11.33.6.2.2.1.5.1.4
Node type: OBJECT-TYPE
Type: DisplayString
Access: read-write
Description: The Name for the Region's configuration.
What is mstNewCfgRegionName?
Sets the MST region name in the pending configuration to control which bridges are grouped into the same Multiple Spanning Tree region. Changing this value takes effect after the new configuration is applied and must match on all bridges intended to share the same MST region.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.3.7.11.33.6.2.2.1.5.1.4 snmpwalk -v2c -c public <target> BLADETYPE6-NETWORK-MIB::mstNewCfgRegionName
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.3.7.11.33.6.2.2.1.5.1.4.1 snmpget -v2c -c public <target> BLADETYPE6-NETWORK-MIB::mstNewCfgRegionName.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.11.2.3.7.11.33.6.2.2.1.5.1.4.1 s <value>
Start monitoring HP BladeSystem Type 6 / ProLiant GbE2c 10G Interconnect Switch with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BLADETYPE6-NETWORK-MIB::mstNewCfgRegionName OID value, configure state conditions and alerts, and monitor any HP BladeSystem Type 6 / ProLiant GbE2c 10G Interconnect Switch from a single console.
OID Breakdown
Upper-level ancestors (14 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.11 | hp | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2 | nm | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2.3 | hpsystem | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2.3.7 | netElement | HP-ICF |
| 1.3.6.1.4.1.11.2.3.7.11 | hpEtherSwitch | HP-ICF-OID |
| 1.3.6.1.4.1.11.2.3.7.11.33 | hpSwitchProliant | HP-ICF-OID |
| 1.3.6.1.4.1.11.2.3.7.11.33.6 | hpSwitchModuleBladetype6 | HP-SWITCH-PL-MIB |
| 1.3.6.1.4.1.11.2.3.7.11.33.6.2 | hpSwitchBladeType6_Mgmt | HP-SWITCH-PL-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.11.2.3.7.11.33.6.2.2 | layer2 | BLADETYPE6-NETWORK-MIB |
| 1.3.6.1.4.1.11.2.3.7.11.33.6.2.2.1 | layer2Configs | BLADETYPE6-NETWORK-MIB |
| 1.3.6.1.4.1.11.2.3.7.11.33.6.2.2.1.5 | mstCfg | BLADETYPE6-NETWORK-MIB |
| 1.3.6.1.4.1.11.2.3.7.11.33.6.2.2.1.5.1 | mstGeneralCfg | BLADETYPE6-NETWORK-MIB |
| 1.3.6.1.4.1.11.2.3.7.11.33.6.2.2.1.5.1.4 | mstNewCfgRegionName | BLADETYPE6-NETWORK-MIB |