BLADE-MIB :: critVolt

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsBLADE-MIBcritVolt

critVolt

Module: BLADE-MIB

OID (symbolic): BLADE-MIB::critVolt

OID (numeric): 1.3.6.1.4.1.2.3.51.2.4.2.1.2

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Generate a alert if any of the monitored power supply sensors in the system fall outside their specified critical operational range.

Note: If a critical voltage condition is detected, the server will automatically be shut down and powered off whether this object is enabled or not.

What is critVolt?

This read-write flag, when enabled, tells the management module to generate a critical alert whenever a monitored power-supply voltage sensor falls outside its specified critical operating range. As with critTemp, the system shuts down and powers off automatically on a critical voltage condition regardless of whether this alert is enabled.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2.3.51.2.4.2.1.2
snmpwalk -v2c -c public <target> BLADE-MIB::critVolt

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2.3.51.2.4.2.1.2.1
snmpget -v2c -c public <target> BLADE-MIB::critVolt.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2.3.51.2.4.2.1.2.1 i <value>

Start monitoring IBM BladeCenter Management Module (MM) (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BLADE-MIB::critVolt OID value, configure state conditions and alerts, and monitor any IBM BladeCenter Management Module (MM) (legacy) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2ibmBLADE-MIB
1.3.6.1.4.1.2.3ibmAgentsBLADE-MIB
1.3.6.1.4.1.2.3.51netfinitySupportProcessorAgentBLADE-MIB
1.3.6.1.4.1.2.3.51.2bladeCenterSnmpMIBBLADE-MIB
1.3.6.1.4.1.2.3.51.2.4configureSPBLADE-MIB
1.3.6.1.4.1.2.3.51.2.4.2remoteAlertsBLADE-MIB
1.3.6.1.4.1.2.3.51.2.4.2.1remoteAlertsCritBLADE-MIB
1.3.6.1.4.1.2.3.51.2.4.2.1.2critVoltBLADE-MIB