All MIBs › BKTEL-HFC862-NECE-MIB › neceStatesPowerSupplyLeft
neceStatesPowerSupplyLeft
Module: BKTEL-HFC862-NECE-MIB
OID (symbolic): BKTEL-HFC862-NECE-MIB::neceStatesPowerSupplyLeft
OID (numeric): 1.3.6.1.4.1.7501.1.2.100.2.1.1.13
Node type: OBJECT-TYPE
Type: PerceivedSeverityValue
Access: read-only
Description: The left (looking from front side) power supply unit fails. Only valid for 2G6 Systems !! Non 2G6 Systems always report clear(5)
What is neceStatesPowerSupplyLeft?
Reports whether the left-hand power supply unit (viewed from the front of the chassis) has failed, as a PerceivedSeverityValue. This is only meaningful on 2G6 systems -- non-2G6 systems always report clear(5) here since they don't have this monitored dual-supply layout.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.7501.1.2.100.2.1.1.13 snmpwalk -v2c -c public <target> BKTEL-HFC862-NECE-MIB::neceStatesPowerSupplyLeft
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.7501.1.2.100.2.1.1.13.1 snmpget -v2c -c public <target> BKTEL-HFC862-NECE-MIB::neceStatesPowerSupplyLeft.1
Start monitoring BKtel optical network elements with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BKTEL-HFC862-NECE-MIB::neceStatesPowerSupplyLeft OID value, configure state conditions and alerts, and monitor any BKtel optical network elements from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.7501 | bktelSystems | BKTEL-HFC862-BASE-MIB |
| 1.3.6.1.4.1.7501.1 | hfc | BKTEL-HFC862-BASE-MIB |
| 1.3.6.1.4.1.7501.1.2 | modules | BKTEL-HFC862-BASE-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.7501.1.2.100 | nece | BKTEL-HFC862-NECE-MIB |
| 1.3.6.1.4.1.7501.1.2.100.2 | neceStates | BKTEL-HFC862-NECE-MIB |
| 1.3.6.1.4.1.7501.1.2.100.2.1 | neceStatesTable | BKTEL-HFC862-NECE-MIB |
| 1.3.6.1.4.1.7501.1.2.100.2.1.1 | neceStatesEntry | BKTEL-HFC862-NECE-MIB |
| 1.3.6.1.4.1.7501.1.2.100.2.1.1.13 | neceStatesPowerSupplyLeft | BKTEL-HFC862-NECE-MIB |