BDCOM-PROCESS-MIB :: bdpmCPUTotal5sec

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › BDCOM-PROCESS-MIB › bdpmCPUTotal5sec

bdpmCPUTotal5sec

Module: BDCOM-PROCESS-MIB

OID (symbolic): BDCOM-PROCESS-MIB::bdpmCPUTotal5sec

OID (numeric): 1.3.6.1.4.1.3320.9.109.1.1.1.1.3

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: The overall CPU busy percentage in the last 5 second period. This object obsoletes the busyPer object from the OLD-CISCO-SYSTEM-MIB. This object is deprecated by bdpmCPUTotal5secRev which has the changed range of value (0..100).

What is bdpmCPUTotal5sec?

Reports the overall CPU busy percentage during the most recent 5-second interval on a BDCOM device. This read-only value is useful for detecting very short bursts of high CPU activity.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3320.9.109.1.1.1.1.3
snmpwalk -v2c -c public <target> BDCOM-PROCESS-MIB::bdpmCPUTotal5sec

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.3320.9.109.1.1.1.1.3.1
snmpget -v2c -c public <target> BDCOM-PROCESS-MIB::bdpmCPUTotal5sec.1

Start monitoring BDCOM networking equipment (switches/routers) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BDCOM-PROCESS-MIB::bdpmCPUTotal5sec OID value, configure state conditions and alerts, and monitor any BDCOM networking equipment (switches/routers) from a single console.

How to Use in IPNetwork Monitor

Select a BDCOM networking equipment (switches/routers) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type bdpmCPUTotal5sec into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The overall CPU busy percentage in the last 5 second period. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Gauge32-type OID, Value bounds is the most useful condition here — trigger an alert if utilization exceeds 85%, a common warning threshold before sustained high load affects performance. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.3320bdcomBDCOM-SMI
1.3.6.1.4.1.3320.9bdMgmtBDCOM-SMI
Numeric OIDNameModule
1.3.6.1.4.1.3320.9.109bdcomProcessMIBBDCOM-PROCESS-MIB
1.3.6.1.4.1.3320.9.109.1bdcomProcessMIBObjectsBDCOM-PROCESS-MIB
1.3.6.1.4.1.3320.9.109.1.1bdpmCPUBDCOM-PROCESS-MIB
1.3.6.1.4.1.3320.9.109.1.1.1bdpmCPUTotalTableBDCOM-PROCESS-MIB
1.3.6.1.4.1.3320.9.109.1.1.1.1bdpmCPUTotalEntryBDCOM-PROCESS-MIB
1.3.6.1.4.1.3320.9.109.1.1.1.1.3bdpmCPUTotal5secBDCOM-PROCESS-MIB