AUTOMATION-SYSTEM-MIB :: automationSystemRestart

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › AUTOMATION-SYSTEM-MIB › automationSystemRestart

automationSystemRestart

Module: AUTOMATION-SYSTEM-MIB

OID (symbolic): AUTOMATION-SYSTEM-MIB::automationSystemRestart

OID (numeric): 1.3.6.1.4.1.4329.6.3.2.1.3.1

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Restart the system. Setting the value to 1 causes a coldstart, a value of 2 causes a warmstart. The different behaviour of coldstart and warmstart depends on the component and is described in the user manual of the component.

If a warmstart is triggered by the values of 3 or 4 the settings of the component will be reseted to factory defaults. The value of 3 means that only the basic parameters will be reseted, the value of 4 causes a complete reset. Which parameters are affected by this action is described in the components manual.

If write access is not allowed, no matter what reason (e.g. an active PROFINET configuration), write requests must be rejected with error 'noSuchName' (SNMPv1 agents) or 'notWriteable' (SNMPv2 and SNMPv3 agents) respectively.

What is automationSystemRestart?

Allows an operator to trigger a system restart by writing a value: 1 initiates a cold start (full power cycle) and 2 initiates a warm start (soft reboot). The exact behavior difference between cold and warm restart is device-specific.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4329.6.3.2.1.3.1
snmpwalk -v2c -c public <target> AUTOMATION-SYSTEM-MIB::automationSystemRestart

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.4329.6.3.2.1.3.1.1
snmpget -v2c -c public <target> AUTOMATION-SYSTEM-MIB::automationSystemRestart.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.4329.6.3.2.1.3.1.1 i <value>

Start monitoring Siemens industrial automation equipment (PLCs, controllers, industrial switches) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the AUTOMATION-SYSTEM-MIB::automationSystemRestart OID value, configure state conditions and alerts, and monitor any Siemens industrial automation equipment (PLCs, controllers, industrial switches) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.4329siemensFSC-RTP-MIB
1.3.6.1.4.1.4329.6automationAUTOMATION-SMI
1.3.6.1.4.1.4329.6.3automationMgmtAUTOMATION-SMI
Numeric OIDNameModule
1.3.6.1.4.1.4329.6.3.2automationSystemMIBAUTOMATION-SYSTEM-MIB
1.3.6.1.4.1.4329.6.3.2.1automationSystemObjectsAUTOMATION-SYSTEM-MIB
1.3.6.1.4.1.4329.6.3.2.1.3automationSystemGenericAUTOMATION-SYSTEM-MIB
1.3.6.1.4.1.4329.6.3.2.1.3.1automationSystemRestartAUTOMATION-SYSTEM-MIB