AS-2000 :: psTelnetLoginTimeout

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsAS-2000psTelnetLoginTimeout

psTelnetLoginTimeout

Module: AS-2000

OID (symbolic): AS-2000::psTelnetLoginTimeout

OID (numeric): 1.3.6.1.4.1.1751.2.4.3.6.18

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Telnet login timeout in seconds. The default value is 30 seconds

What is psTelnetLoginTimeout?

This integer (1-60 seconds) limits how long a user can take to log in via Telnet. After this timeout, the connection is dropped. Example: 30 seconds prevents brute-force attacks.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1751.2.4.3.6.18
snmpwalk -v2c -c public <target> AS-2000::psTelnetLoginTimeout

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1751.2.4.3.6.18.1
snmpget -v2c -c public <target> AS-2000::psTelnetLoginTimeout.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.1751.2.4.3.6.18.1 i <value>

Start monitoring Lucent AS-2000 wireless access server platform (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the AS-2000::psTelnetLoginTimeout OID value, configure state conditions and alerts, and monitor any Lucent AS-2000 wireless access server platform (legacy) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1751lucentACMIB
1.3.6.1.4.1.1751.2mibsACMIB
Numeric OIDNameModule
1.3.6.1.4.1.1751.2.4orinocoAS-2000
1.3.6.1.4.1.1751.2.4.3as2000AS-2000
1.3.6.1.4.1.1751.2.4.3.6orinocoAgentAS-2000
1.3.6.1.4.1.1751.2.4.3.6.18psTelnetLoginTimeoutAS-2000