AS-2000 :: psIappMaxHandOvrRetries

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsAS-2000psIappMaxHandOvrRetries

psIappMaxHandOvrRetries

Module: AS-2000

OID (symbolic): AS-2000::psIappMaxHandOvrRetries

OID (numeric): 1.3.6.1.4.1.1751.2.4.3.11.19

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This parameter indicates the maximum amount of retransmission sent by the device for a handover request message. The default for this parameter should be 2.

What is psIappMaxHandOvrRetries?

This integer (1-4) specifies the maximum handover retransmission attempts. Default: 2. Higher values ensure delivery but delay failure. Example: 3 retries for reliability.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1751.2.4.3.11.19
snmpwalk -v2c -c public <target> AS-2000::psIappMaxHandOvrRetries

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1751.2.4.3.11.19.1
snmpget -v2c -c public <target> AS-2000::psIappMaxHandOvrRetries.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.1751.2.4.3.11.19.1 i <value>

Start monitoring Lucent AS-2000 wireless access server platform (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the AS-2000::psIappMaxHandOvrRetries OID value, configure state conditions and alerts, and monitor any Lucent AS-2000 wireless access server platform (legacy) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1751lucentACMIB
1.3.6.1.4.1.1751.2mibsACMIB
Numeric OIDNameModule
1.3.6.1.4.1.1751.2.4orinocoAS-2000
1.3.6.1.4.1.1751.2.4.3as2000AS-2000
1.3.6.1.4.1.1751.2.4.3.11orinocoIAPPAS-2000
1.3.6.1.4.1.1751.2.4.3.11.19psIappMaxHandOvrRetriesAS-2000