APTIS-MONITOR-MIB :: dacClockingClockSourceSecondary

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsAPTIS-MONITOR-MIBdacClockingClockSourceSecondary

dacClockingClockSourceSecondary

Module: APTIS-MONITOR-MIB

OID (symbolic): APTIS-MONITOR-MIB::dacClockingClockSourceSecondary

OID (numeric): 1.3.6.1.4.1.2637.2.2.2050.1.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: DAC Secondary Clocking Source.

What is dacClockingClockSourceSecondary?

This specifies the DAC's backup clock source interface. Secondary activates if primary fails. Secondary source if6 provides failover timing if primary if2 becomes unavailable.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2637.2.2.2050.1.3
snmpwalk -v2c -c public <target> APTIS-MONITOR-MIB::dacClockingClockSourceSecondary

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2637.2.2.2050.1.3.1
snmpget -v2c -c public <target> APTIS-MONITOR-MIB::dacClockingClockSourceSecondary.1

Start monitoring Nortel Networks Aptis DSL concentrator/access multiplexer (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the APTIS-MONITOR-MIB::dacClockingClockSourceSecondary OID value, configure state conditions and alerts, and monitor any Nortel Networks Aptis DSL concentrator/access multiplexer (legacy) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2637aptisAPTIS-MIB
1.3.6.1.4.1.2637.2aptis_genericAPTIS-MIB
1.3.6.1.4.1.2637.2.2aptis_monitoringAPTIS-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2637.2.2.2050dacClockingTableAPTIS-MONITOR-MIB
1.3.6.1.4.1.2637.2.2.2050.1dacClockingEntryAPTIS-MONITOR-MIB
1.3.6.1.4.1.2637.2.2.2050.1.3dacClockingClockSourceSecondaryAPTIS-MONITOR-MIB