All MIBs › APRISAXE-MIB-4RF › aprisaXETxADCChOneLoAlarmName
aprisaXETxADCChOneLoAlarmName
Module: APRISAXE-MIB-4RF
OID (symbolic): APRISAXE-MIB-4RF::aprisaXETxADCChOneLoAlarmName
OID (numeric): 1.3.6.1.4.1.14817.7.3.1.2.86.1.26.1
Node type: OBJECT-TYPE
Type: DisplayString
Access: read-only
Description: The name of the transmitter ADC Ch One voltage too low alarm.
What is aprisaXETxADCChOneLoAlarmName?
Provides the descriptive name of the alarm that fires when the transmitter's ADC Channel One voltage drops below the acceptable lower limit. This label identifies the alarm in management system logs and notifications.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.14817.7.3.1.2.86.1.26.1 snmpwalk -v2c -c public <target> APRISAXE-MIB-4RF::aprisaXETxADCChOneLoAlarmName
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.14817.7.3.1.2.86.1.26.1.1 snmpget -v2c -c public <target> APRISAXE-MIB-4RF::aprisaXETxADCChOneLoAlarmName.1
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> aprisaXETxADCChOneLoAlarmName.1
Start monitoring 4RF Aprisa XE point-to-point microwave/radio terminal with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the APRISAXE-MIB-4RF::aprisaXETxADCChOneLoAlarmName OID value, configure state conditions and alerts, and monitor any 4RF Aprisa XE point-to-point microwave/radio terminal from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.14817 | fourRFRoot | MIB-4RF |
| 1.3.6.1.4.1.14817.7 | fourRFExperimental | MIB-4RF |
| 1.3.6.1.4.1.14817.7.3 | fourRFAprisaXE | PRODUCTS-MIB-4RF |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.14817.7.3.1 | aprisaXEConfig | APRISAXE-MIB-4RF |
| 1.3.6.1.4.1.14817.7.3.1.2 | aprisaXEObjects | APRISAXE-MIB-4RF |
| 1.3.6.1.4.1.14817.7.3.1.2.86 | aprisaXELinkAlarms | APRISAXE-MIB-4RF |
| 1.3.6.1.4.1.14817.7.3.1.2.86.1 | aprisaXETransmitterAlarms | APRISAXE-MIB-4RF |
| 1.3.6.1.4.1.14817.7.3.1.2.86.1.26 | aprisaXETxADCChOneLoAlarm | APRISAXE-MIB-4RF |
| 1.3.6.1.4.1.14817.7.3.1.2.86.1.26.1 | aprisaXETxADCChOneLoAlarmName | APRISAXE-MIB-4RF |