APEX-MIB :: apexQamModuleStatError

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsAPEX-MIBapexQamModuleStatError

apexQamModuleStatError

Module: APEX-MIB

OID (symbolic): APEX-MIB::apexQamModuleStatError

OID (numeric): 1.3.6.1.4.1.1166.1.31.8.2.2.1.7

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Summary of errors reported on an QAM Module basis.

These errors are reported in apexAlarmQamModuleFault.

ok - No errors. removed - Reflects apexQamModuleStatInstalled. unsupported - Reflects apexQamModuleStatInstalled. notInstalled - Reflects apexQamModuleStatInstalled. powerFault - Reflects apexQamModuleStatPowerFault. offline - Indicates the QAM Module and the RF Ports on it are being brought to operational mode after module is inserted or the module has recovered from a power fault. dc5VoltError - 5 Vdc error, see also apexQamModuleStat5VdcSupply and apexQamModuleStat5VdcFault. dc3-3VoltError - 3.3 Vdc error, see also apexQamModuleStat3dot3VdcSupply and apexQamModuleStat3dot3VdcFault. commLost - Communication Lost, see also apexQamModuleStatCommError. codeVersions - Incorrect Code Versions on module, see also apexQamModuleStatCodeInitError, apexQamQrmRevisionTable, and apexQamQrmRevisionStatusTable. codeDownload - Code Download In Progress, see also apexQrmDownloadStatusTable. codeDownloadError - Code Download Error, see also apexQrmDownloadStatusTable.

What is apexQamModuleStatError?

Provides a per-module summary of error conditions for a QAM module, including states such as 'ok', 'removed', 'unsupported', and others. These errors are aggregated and reported under the apexAlarmQamModuleFault alarm.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1166.1.31.8.2.2.1.7
snmpwalk -v2c -c public <target> APEX-MIB::apexQamModuleStatError

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1166.1.31.8.2.2.1.7.1
snmpget -v2c -c public <target> APEX-MIB::apexQamModuleStatError.1

Start monitoring BigBand Networks APEX video/broadband gateway (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the APEX-MIB::apexQamModuleStatError OID value, configure state conditions and alerts, and monitor any BigBand Networks APEX video/broadband gateway (legacy) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1166giBCS-IDENT-MIB
1.3.6.1.4.1.1166.1giproductsBCS-IDENT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1166.1.31apexAPEX-MIB
1.3.6.1.4.1.1166.1.31.8apexQamAPEX-MIB
1.3.6.1.4.1.1166.1.31.8.2apexQamStatusAPEX-MIB
1.3.6.1.4.1.1166.1.31.8.2.2apexQamModuleStatusTableAPEX-MIB
1.3.6.1.4.1.1166.1.31.8.2.2.1apexQamModuleStatusEntryAPEX-MIB
1.3.6.1.4.1.1166.1.31.8.2.2.1.7apexQamModuleStatErrorAPEX-MIB