apexOutputTsConfOperatingMode

Module: APEX-MIB

OID (symbolic): APEX-MIB::apexOutputTsConfOperatingMode

OID (numeric): 1.3.6.1.4.1.1166.1.31.14.1.6.1.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This parameter is used to set the operating mode of the output.

Operating mode changes can only occur when the output is not in use (no service, PID, or stream mapping active to the output). Session Control - User must select either RTSP or RPC to communicate with external resource manager. All service mappings on output are controlled by the external manager. - Only valid when Encryption Type is set to CTE or None - Only valid when Simulcrypt Mode is set to None - PID Remapping mode should be Enabled (Without Reuse)

Manual Routing - User manually maps each service - Encryption Type can be any valid setting (none, CTE, or Broadcast) - Simulcrypt Mode must be None or External EIS

UDP Port Mapping - Standard UDP Port Mapping for use with VOD servers. Uses specific algorithm based on UDP Port to determine output program mappings. - Encryption Type must be None or CTE (broadcast not supported) - Simulcrypt Mode must be None or External EIS

Operating mode changes can only occur when the output is not in use (no service, PID, or stream mapping active to the output).

@Commit(param=apexOutputTsConfApplyChange, value=2)

What is apexOutputTsConfOperatingMode?

Configures the operational mode of an Output Transport Stream, such as session-controlled (RTSP or RPC) or manual routing modes. The mode can only be changed when no services, PIDs, or streams are actively mapped to the output.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1166.1.31.14.1.6.1.3
snmpwalk -v2c -c public <target> APEX-MIB::apexOutputTsConfOperatingMode

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1166.1.31.14.1.6.1.3.1
snmpget -v2c -c public <target> APEX-MIB::apexOutputTsConfOperatingMode.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.1166.1.31.14.1.6.1.3.1 i <value>

Start monitoring BigBand Networks APEX video/broadband gateway (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the APEX-MIB::apexOutputTsConfOperatingMode OID value, configure state conditions and alerts, and monitor any BigBand Networks APEX video/broadband gateway (legacy) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1166giBCS-IDENT-MIB
1.3.6.1.4.1.1166.1giproductsBCS-IDENT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1166.1.31apexAPEX-MIB
1.3.6.1.4.1.1166.1.31.14apexOutputTransportAPEX-MIB
1.3.6.1.4.1.1166.1.31.14.1apexOutputTsConfigAPEX-MIB
1.3.6.1.4.1.1166.1.31.14.1.6apexOutputTsConfigTableAPEX-MIB
1.3.6.1.4.1.1166.1.31.14.1.6.1apexOutputTsConfigEntryAPEX-MIB
1.3.6.1.4.1.1166.1.31.14.1.6.1.3apexOutputTsConfOperatingModeAPEX-MIB