APEX-MIB :: apexManRteGbeInRedForceSwitch

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsAPEX-MIBapexManRteGbeInRedForceSwitch

apexManRteGbeInRedForceSwitch

Module: APEX-MIB

OID (symbolic): APEX-MIB::apexManRteGbeInRedForceSwitch

OID (numeric): 1.3.6.1.4.1.1166.1.31.10.1.6.4.1.2

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: The Gigabit Ethernet Redundant Pair force switch.

This will have no effect if the corresponding row setting of apexManRteGbeInRedEnable is 'disabled'.

The corresponding row setting apexManRteGbeInRedSuspend is ignored when 'forceSwitch' is set. The switch will occur even if apexManRteGbeInRedSuspend is 'suspended'.

When forced to the Secondary of the pair, the APEX will stay on the Secondary until the user forces back to the Primary. The APEX will not automatically switch back to the Primary when the Primary is restored above the failover threshold.

The APEX will not allow a force to the Primary unless the Primary is above the failover threshold.

Once written, the change to this parameter will take immediate effect.

@Config(config=no, reboot=no)

What is apexManRteGbeInRedForceSwitch?

Allows an operator to manually force a switchover between the primary and secondary Gigabit Ethernet inputs in a redundant pair, overriding any suspension setting. This control has no effect if redundancy is disabled for the corresponding entry.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1166.1.31.10.1.6.4.1.2
snmpwalk -v2c -c public <target> APEX-MIB::apexManRteGbeInRedForceSwitch

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1166.1.31.10.1.6.4.1.2.1
snmpget -v2c -c public <target> APEX-MIB::apexManRteGbeInRedForceSwitch.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.1166.1.31.10.1.6.4.1.2.1 i <value>

Start monitoring BigBand Networks APEX video/broadband gateway (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the APEX-MIB::apexManRteGbeInRedForceSwitch OID value, configure state conditions and alerts, and monitor any BigBand Networks APEX video/broadband gateway (legacy) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1166giBCS-IDENT-MIB
1.3.6.1.4.1.1166.1giproductsBCS-IDENT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1166.1.31apexAPEX-MIB
1.3.6.1.4.1.1166.1.31.10apexManualRoutingAPEX-MIB
1.3.6.1.4.1.1166.1.31.10.1apexManualRoutingConfigAPEX-MIB
1.3.6.1.4.1.1166.1.31.10.1.6apexManualRouteGbeInputRedundConfigAPEX-MIB
1.3.6.1.4.1.1166.1.31.10.1.6.4apexManRteGbeInRedForceSwitchTableAPEX-MIB
1.3.6.1.4.1.1166.1.31.10.1.6.4.1apexManRteGbeInRedForceSwitchEntryAPEX-MIB
1.3.6.1.4.1.1166.1.31.10.1.6.4.1.2apexManRteGbeInRedForceSwitchAPEX-MIB