All MIBs › APEX-MIB › apexEnableChassisRedundancySecondaryFailover
apexEnableChassisRedundancySecondaryFailover
Module: APEX-MIB
OID (symbolic): APEX-MIB::apexEnableChassisRedundancySecondaryFailover
OID (numeric): 1.3.6.1.4.1.1166.1.31.102.1.8091
Node type: OBJECT-TYPE
Type: EnableDisableTYPE
Access: read-write
Description: This setting enables or disables apexEnableChassisRedundancySecondaryFailover. When set to 'enabled' the alarm will operate as described.
When set to 'disabled' the alarm will not be reported or wrapped into unitAlarmStatus and the alarm condition will remain 'ok'. If the alarm condition is not 'ok' when it is 'disabled', the alarm will be cleared.
Once written, the change to this parameter will take immediate effect. However, in order for the change to persist through subsequent reboots or power cycles, the change must be saved via the apexSaveConfig parameter.
@Config(config=yes, reboot=no) @Save(apexSaveConfig, value=2) @File(config.ini, type='ini')
What is apexEnableChassisRedundancySecondaryFailover?
Controls whether the chassis redundancy secondary failover alarm is reported. When enabled, an alarm fires if the secondary chassis unit experiences a failover; disabling it suppresses all reporting of that condition.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1166.1.31.102.1.8091 snmpwalk -v2c -c public <target> APEX-MIB::apexEnableChassisRedundancySecondaryFailover
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.1166.1.31.102.1.8091.1 snmpget -v2c -c public <target> APEX-MIB::apexEnableChassisRedundancySecondaryFailover.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.1166.1.31.102.1.8091.1 s <value>
Start monitoring BigBand Networks APEX video/broadband gateway (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the APEX-MIB::apexEnableChassisRedundancySecondaryFailover OID value, configure state conditions and alerts, and monitor any BigBand Networks APEX video/broadband gateway (legacy) from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.1166 | gi | BCS-IDENT-MIB |
| 1.3.6.1.4.1.1166.1 | giproducts | BCS-IDENT-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.1166.1.31 | apex | APEX-MIB |
| 1.3.6.1.4.1.1166.1.31.102 | apexConfigAlarms | APEX-MIB |
| 1.3.6.1.4.1.1166.1.31.102.1 | apexConfAlarmEnable | APEX-MIB |
| 1.3.6.1.4.1.1166.1.31.102.1.8091 | apexEnableChassisRedundancySecondaryFailover | APEX-MIB |