apexEnableChassisRedundancyConfigurationFault

Module: APEX-MIB

OID (symbolic): APEX-MIB::apexEnableChassisRedundancyConfigurationFault

OID (numeric): 1.3.6.1.4.1.1166.1.31.102.1.8094

Node type: OBJECT-TYPE

Type: EnableDisableTYPE

Access: read-write

Description: This setting enables or disables apexEnableChassisRedundancyConfigurationFault. When set to 'enabled' the alarm will operate as described.

When set to 'disabled' the alarm will not be reported or wrapped into unitAlarmStatus and the alarm condition will remain 'ok'. If the alarm condition is not 'ok' when it is 'disabled', the alarm will be cleared.

Once written, the change to this parameter will take immediate effect. However, in order for the change to persist through subsequent reboots or power cycles, the change must be saved via the apexSaveConfig parameter.

@Config(config=yes, reboot=no) @Save(apexSaveConfig, value=2) @File(config.ini, type='ini')

What is apexEnableChassisRedundancyConfigurationFault?

Controls whether the chassis redundancy configuration fault alarm is active. When enabled, a mismatch or error in the chassis redundancy configuration triggers an alarm; disabling it prevents any such configuration fault from being reported.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1166.1.31.102.1.8094
snmpwalk -v2c -c public <target> APEX-MIB::apexEnableChassisRedundancyConfigurationFault

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1166.1.31.102.1.8094.1
snmpget -v2c -c public <target> APEX-MIB::apexEnableChassisRedundancyConfigurationFault.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.1166.1.31.102.1.8094.1 s <value>

Start monitoring BigBand Networks APEX video/broadband gateway (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the APEX-MIB::apexEnableChassisRedundancyConfigurationFault OID value, configure state conditions and alerts, and monitor any BigBand Networks APEX video/broadband gateway (legacy) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1166giBCS-IDENT-MIB
1.3.6.1.4.1.1166.1giproductsBCS-IDENT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1166.1.31apexAPEX-MIB
1.3.6.1.4.1.1166.1.31.102apexConfigAlarmsAPEX-MIB
1.3.6.1.4.1.1166.1.31.102.1apexConfAlarmEnableAPEX-MIB
1.3.6.1.4.1.1166.1.31.102.1.8094apexEnableChassisRedundancyConfigurationFaultAPEX-MIB