ALPHA-NOTIFICATION-MIB :: alphaAlarmActiveState

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › ALPHA-NOTIFICATION-MIB › alphaAlarmActiveState

alphaAlarmActiveState

Module: ALPHA-NOTIFICATION-MIB

OID (symbolic): ALPHA-NOTIFICATION-MIB::alphaAlarmActiveState

OID (numeric): 1.3.6.1.4.1.7309.100.1

Node type: NOTIFICATION-TYPE

Description: SNMPv2 notification varbinds start with SysUptime and Notification Oid as the first two in the list by default. The first varbind in this definition would be the third varbind in the raw output of the notification.

An instance of the alarm indicated by alarmActiveModelPointer has been raised against the entity indicated by alarmActiveResourceId.

The state of the alarm is indicated by the alarmModelState.

The description of the alarm along with its source is indicated by the alarmModelDescription and componentListStaticName respectively.

componentListSnmpId provides the Id set to the source of the alarm.

The agent must throttle the generation of consecutive alarmActiveState traps so that there is at least a two-second gap between traps of this type against the same alarmActiveModelPointer and alarmActiveResourceId. When traps are throttled, they are queued for sending at a future time.

A management application should periodically check the value of alarmActiveLastChanged to detect any missed alarmActiveState notification-events, e.g., due to throttling or transmission loss.

Examples

Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):

snmptrap -v2c -c public <manager> '' ALPHA-NOTIFICATION-MIB::alphaAlarmActiveState
snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.7309.100.1

Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):

snmptrapd -f -Lo -c /dev/null authCommunity log public

Example snmptrapd log entry:

zoo11-linux.zoo [UDP: [192.168.30.111]:63321->[192.168.30.10]:162]:
  DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (163176793) 18 days, 21:16:07.93
  SNMPv2-MIB::snmpTrapOID.0 = OID: ALPHA-NOTIFICATION-MIB::alphaAlarmActiveState

Start monitoring Alpha Technologies power system controllers (UPS/DC power plants) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ALPHA-NOTIFICATION-MIB::alphaAlarmActiveState OID value, configure state conditions and alerts, and monitor any Alpha Technologies power system controllers (UPS/DC power plants) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.7309alphaALPHA-RESOURCE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.7309.100alphaAlarmNotificationsALPHA-NOTIFICATION-MIB
1.3.6.1.4.1.7309.100.1alphaAlarmActiveStateALPHA-NOTIFICATION-MIB