ADTRAN-AOS-IF :: adGenAOSInInvalidCeVlanIdDrops

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › ADTRAN-AOS-IF › adGenAOSInInvalidCeVlanIdDrops

adGenAOSInInvalidCeVlanIdDrops

Module: ADTRAN-AOS-IF

OID (symbolic): ADTRAN-AOS-IF::adGenAOSInInvalidCeVlanIdDrops

OID (numeric): 1.3.6.1.4.1.664.5.53.2.4.1.1.13

Node type: OBJECT-TYPE

Type: Counter64

Access: read-only

Description: Number of frames dropped which were received with an Invalid CE-VLAN-ID.

What is adGenAOSInInvalidCeVlanIdDrops?

This OID counts the total number of incoming frames discarded because they contained an invalid Customer Equipment VLAN identifier, stored as a 64-bit counter. Network engineers monitor this to troubleshoot VLAN configuration errors or detect traffic being sent with incorrect VLAN tags that the interface must reject. If this counter rapidly increases, it suggests an upstream device is sending frames with wrong VLAN tags that don't match the interface's configuration.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.664.5.53.2.4.1.1.13
snmpwalk -v2c -c public <target> ADTRAN-AOS-IF::adGenAOSInInvalidCeVlanIdDrops

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.664.5.53.2.4.1.1.13.1
snmpget -v2c -c public <target> ADTRAN-AOS-IF::adGenAOSInInvalidCeVlanIdDrops.1

Start monitoring ADTRAN NetVanta/SDG-series AOS devices with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADTRAN-AOS-IF::adGenAOSInInvalidCeVlanIdDrops OID value, configure state conditions and alerts, and monitor any ADTRAN NetVanta/SDG-series AOS devices from a single console.

How to Use in IPNetwork Monitor

Select an ADTRAN NetVanta/SDG-series AOS device as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type adGenAOSInInvalidCeVlanIdDrops into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. It reports the number of frames dropped which were received with an Invalid CE-VLAN-ID. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter64-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases between polls, since a rising count of errors, failures, or discards often points to a real underlying problem. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.664adtranADTRAN-ACTDAX-MIB
1.3.6.1.4.1.664.5adSharedADTRAN-MIB
1.3.6.1.4.1.664.5.53adGenAOSADTRAN-AOS
1.3.6.1.4.1.664.5.53.2adGenAOSRouterADTRAN-AOS
Numeric OIDNameModule
1.3.6.1.4.1.664.5.53.2.4adGenAOSIfADTRAN-AOS-IF
1.3.6.1.4.1.664.5.53.2.4.1adGenAOSIfTableADTRAN-AOS-IF
1.3.6.1.4.1.664.5.53.2.4.1.1adGenAOSIfEntryADTRAN-AOS-IF
1.3.6.1.4.1.664.5.53.2.4.1.1.13adGenAOSInInvalidCeVlanIdDropsADTRAN-AOS-IF