All MIBs › ADIC-INTELLIGENT-STORAGE-MIB › voltageSensorWarningHi
voltageSensorWarningHi
Module: ADIC-INTELLIGENT-STORAGE-MIB
OID (symbolic): ADIC-INTELLIGENT-STORAGE-MIB::voltageSensorWarningHi
OID (numeric): 1.3.6.1.4.1.3764.1.1.200.200.20.1.9
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: ** This object is optional ** Upper voltage limit of the warning state for this voltage sensor. Unit are millivolts. If the voltage rises above this limit, the sensor enters the alarm state.
What is voltageSensorWarningHi?
This OID defines the upper voltage threshold in millivolts that triggers a warning alert if the voltage rises above it (more critical than nominal). A network engineer sets this as an early-warning trigger for overvoltage conditions that could damage sensitive components if allowed to continue. For example, if nominal-high is 12.3V, the warning threshold might be set to 12.6V to notify operators of a developing overvoltage condition.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3764.1.1.200.200.20.1.9 snmpwalk -v2c -c public <target> ADIC-INTELLIGENT-STORAGE-MIB::voltageSensorWarningHi
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.3764.1.1.200.200.20.1.9.1 snmpget -v2c -c public <target> ADIC-INTELLIGENT-STORAGE-MIB::voltageSensorWarningHi.1
Start monitoring ADIC (Quantum) storage products with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADIC-INTELLIGENT-STORAGE-MIB::voltageSensorWarningHi OID value, configure state conditions and alerts, and monitor any ADIC (Quantum) storage products from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.3764 | adic | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1 | storage | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1 | intelligent | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1.200 | hardware | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1.200.200 | powerAndCooling | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1.200.200.20 | voltageSensorTable | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1.200.200.20.1 | voltageSensorEntry | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1.200.200.20.1.9 | voltageSensorWarningHi | ADIC-INTELLIGENT-STORAGE-MIB |