All MIBs › ADIC-INTELLIGENT-STORAGE-MIB › voltageSensorStatus
voltageSensorStatus
Module: ADIC-INTELLIGENT-STORAGE-MIB
OID (symbolic): ADIC-INTELLIGENT-STORAGE-MIB::voltageSensorStatus
OID (numeric): 1.3.6.1.4.1.3764.1.1.200.200.20.1.3
Node type: OBJECT-TYPE
Type: AdicSensorStatus
Access: read-only
Description: ** This object is optional ** What is the state of this voltage sensor? Is the voltage in the nominal, warning or alarm region?
What is voltageSensorStatus?
This OID reports the current health state of the voltage sensor as nominal (within expected range), warning (approaching limits), or alarm (out of safe limits). A network engineer sets up alerts based on this value to detect power distribution problems before they cause hardware damage or service disruption. For example, a status of 'alarm' indicates the voltage has drifted dangerously far from specification and immediate action is needed.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3764.1.1.200.200.20.1.3 snmpwalk -v2c -c public <target> ADIC-INTELLIGENT-STORAGE-MIB::voltageSensorStatus
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.3764.1.1.200.200.20.1.3.1 snmpget -v2c -c public <target> ADIC-INTELLIGENT-STORAGE-MIB::voltageSensorStatus.1
Start monitoring ADIC (Quantum) storage products with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADIC-INTELLIGENT-STORAGE-MIB::voltageSensorStatus OID value, configure state conditions and alerts, and monitor any ADIC (Quantum) storage products from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.3764 | adic | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1 | storage | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1 | intelligent | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1.200 | hardware | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1.200.200 | powerAndCooling | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1.200.200.20 | voltageSensorTable | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1.200.200.20.1 | voltageSensorEntry | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1.200.200.20.1.3 | voltageSensorStatus | ADIC-INTELLIGENT-STORAGE-MIB |