All MIBs › ADIC-INTELLIGENT-STORAGE-MIB › voltageSensorNominalLo
voltageSensorNominalLo
Module: ADIC-INTELLIGENT-STORAGE-MIB
OID (symbolic): ADIC-INTELLIGENT-STORAGE-MIB::voltageSensorNominalLo
OID (numeric): 1.3.6.1.4.1.3764.1.1.200.200.20.1.6
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: ** This object is optional ** Lower voltage limit of the nominal state for this voltage sensor. Unit are millivolts.
What is voltageSensorNominalLo?
This OID sets the lower bound of the acceptable voltage range in millivolts for this sensor, defining the floor of normal operation. A network engineer uses this threshold (along with the upper bound) to configure alert conditions and to validate that a voltage sensor is correctly configured for its power rail. For example, a value of 11700 mV (11.7V) on a 12V rail means the sensor considers anything below 11.7V as abnormal.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3764.1.1.200.200.20.1.6 snmpwalk -v2c -c public <target> ADIC-INTELLIGENT-STORAGE-MIB::voltageSensorNominalLo
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.3764.1.1.200.200.20.1.6.1 snmpget -v2c -c public <target> ADIC-INTELLIGENT-STORAGE-MIB::voltageSensorNominalLo.1
Start monitoring ADIC (Quantum) storage products with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADIC-INTELLIGENT-STORAGE-MIB::voltageSensorNominalLo OID value, configure state conditions and alerts, and monitor any ADIC (Quantum) storage products from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.3764 | adic | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1 | storage | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1 | intelligent | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1.200 | hardware | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1.200.200 | powerAndCooling | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1.200.200.20 | voltageSensorTable | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1.200.200.20.1 | voltageSensorEntry | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1.200.200.20.1.6 | voltageSensorNominalLo | ADIC-INTELLIGENT-STORAGE-MIB |