All MIBs › ADIC-INTELLIGENT-STORAGE-MIB › voltageSensorNominalHi
voltageSensorNominalHi
Module: ADIC-INTELLIGENT-STORAGE-MIB
OID (symbolic): ADIC-INTELLIGENT-STORAGE-MIB::voltageSensorNominalHi
OID (numeric): 1.3.6.1.4.1.3764.1.1.200.200.20.1.7
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: ** This object is optional ** Upper voltage limit of the nominal state for this voltage sensor. Unit are millivolts.
What is voltageSensorNominalHi?
This OID sets the upper bound of the acceptable voltage range in millivolts, defining the ceiling of normal operation for this sensor. A network engineer refers to this value when setting monitoring thresholds to distinguish between normal operation and power issues. For example, a value of 12300 mV (12.3V) on a 12V rail means anything above 12.3V is flagged as out of nominal range.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3764.1.1.200.200.20.1.7 snmpwalk -v2c -c public <target> ADIC-INTELLIGENT-STORAGE-MIB::voltageSensorNominalHi
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.3764.1.1.200.200.20.1.7.1 snmpget -v2c -c public <target> ADIC-INTELLIGENT-STORAGE-MIB::voltageSensorNominalHi.1
Start monitoring ADIC (Quantum) storage products with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADIC-INTELLIGENT-STORAGE-MIB::voltageSensorNominalHi OID value, configure state conditions and alerts, and monitor any ADIC (Quantum) storage products from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.3764 | adic | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1 | storage | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1 | intelligent | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1.200 | hardware | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1.200.200 | powerAndCooling | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1.200.200.20 | voltageSensorTable | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1.200.200.20.1 | voltageSensorEntry | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1.200.200.20.1.7 | voltageSensorNominalHi | ADIC-INTELLIGENT-STORAGE-MIB |