ADIC-INTELLIGENT-STORAGE-MIB :: voltageSensorMillivolts

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADIC-INTELLIGENT-STORAGE-MIBvoltageSensorMillivolts

voltageSensorMillivolts

Module: ADIC-INTELLIGENT-STORAGE-MIB

OID (symbolic): ADIC-INTELLIGENT-STORAGE-MIB::voltageSensorMillivolts

OID (numeric): 1.3.6.1.4.1.3764.1.1.200.200.20.1.4

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: ** This object is optional ** What is the voltage in millivolts of this voltage sensor?

What is voltageSensorMillivolts?

This OID provides the real-time voltage reading from the sensor in millivolts, giving you the actual power line voltage at a specific point in the system. A network engineer monitors this value continuously via SNMP polling to detect power instability, ripple, or gradual voltage sag that might indicate a failing power supply. For example, a value of 12087 means the voltage is reading 12.087 volts at that sensor location.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3764.1.1.200.200.20.1.4
snmpwalk -v2c -c public <target> ADIC-INTELLIGENT-STORAGE-MIB::voltageSensorMillivolts

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.3764.1.1.200.200.20.1.4.1
snmpget -v2c -c public <target> ADIC-INTELLIGENT-STORAGE-MIB::voltageSensorMillivolts.1

Start monitoring ADIC (Quantum) storage products with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADIC-INTELLIGENT-STORAGE-MIB::voltageSensorMillivolts OID value, configure state conditions and alerts, and monitor any ADIC (Quantum) storage products from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.3764adicADIC-INTELLIGENT-STORAGE-MIB
1.3.6.1.4.1.3764.1storageADIC-INTELLIGENT-STORAGE-MIB
1.3.6.1.4.1.3764.1.1intelligentADIC-INTELLIGENT-STORAGE-MIB
1.3.6.1.4.1.3764.1.1.200hardwareADIC-INTELLIGENT-STORAGE-MIB
1.3.6.1.4.1.3764.1.1.200.200powerAndCoolingADIC-INTELLIGENT-STORAGE-MIB
1.3.6.1.4.1.3764.1.1.200.200.20voltageSensorTableADIC-INTELLIGENT-STORAGE-MIB
1.3.6.1.4.1.3764.1.1.200.200.20.1voltageSensorEntryADIC-INTELLIGENT-STORAGE-MIB
1.3.6.1.4.1.3764.1.1.200.200.20.1.4voltageSensorMillivoltsADIC-INTELLIGENT-STORAGE-MIB