All MIBs › ADIC-INTELLIGENT-STORAGE-MIB › temperatureSensorWarningLo
temperatureSensorWarningLo
Module: ADIC-INTELLIGENT-STORAGE-MIB
OID (symbolic): ADIC-INTELLIGENT-STORAGE-MIB::temperatureSensorWarningLo
OID (numeric): 1.3.6.1.4.1.3764.1.1.200.200.30.1.7
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: ** This object is optional ** Lower temperature limit of the warning state for this temperature sensor. Unit are degrees Celsius. If the temperature falls below this limit, the sensor enters the alarm state.
What is temperatureSensorWarningLo?
This OID stores the lower temperature limit (in degrees Celsius) that triggers a warning state for a temperature sensor. Network engineers monitor and set this threshold to ensure equipment doesn't run too cold, which can affect performance or cause condensation. For example, a setting of 5°C means the storage system will generate an alert if the sensor detects temperatures dropping below this point.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3764.1.1.200.200.30.1.7 snmpwalk -v2c -c public <target> ADIC-INTELLIGENT-STORAGE-MIB::temperatureSensorWarningLo
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.3764.1.1.200.200.30.1.7.1 snmpget -v2c -c public <target> ADIC-INTELLIGENT-STORAGE-MIB::temperatureSensorWarningLo.1
Start monitoring ADIC (Quantum) storage products with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADIC-INTELLIGENT-STORAGE-MIB::temperatureSensorWarningLo OID value, configure state conditions and alerts, and monitor any ADIC (Quantum) storage products from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.3764 | adic | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1 | storage | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1 | intelligent | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1.200 | hardware | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1.200.200 | powerAndCooling | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1.200.200.30 | temperatureSensorTable | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1.200.200.30.1 | temperatureSensorEntry | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1.200.200.30.1.7 | temperatureSensorWarningLo | ADIC-INTELLIGENT-STORAGE-MIB |