temperatureSensorWarningLo

Module: ADIC-INTELLIGENT-STORAGE-MIB

OID (symbolic): ADIC-INTELLIGENT-STORAGE-MIB::temperatureSensorWarningLo

OID (numeric): 1.3.6.1.4.1.3764.1.1.200.200.30.1.7

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: ** This object is optional ** Lower temperature limit of the warning state for this temperature sensor. Unit are degrees Celsius. If the temperature falls below this limit, the sensor enters the alarm state.

What is temperatureSensorWarningLo?

This OID stores the lower temperature limit (in degrees Celsius) that triggers a warning state for a temperature sensor. Network engineers monitor and set this threshold to ensure equipment doesn't run too cold, which can affect performance or cause condensation. For example, a setting of 5°C means the storage system will generate an alert if the sensor detects temperatures dropping below this point.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3764.1.1.200.200.30.1.7
snmpwalk -v2c -c public <target> ADIC-INTELLIGENT-STORAGE-MIB::temperatureSensorWarningLo

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.3764.1.1.200.200.30.1.7.1
snmpget -v2c -c public <target> ADIC-INTELLIGENT-STORAGE-MIB::temperatureSensorWarningLo.1

Start monitoring ADIC (Quantum) storage products with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADIC-INTELLIGENT-STORAGE-MIB::temperatureSensorWarningLo OID value, configure state conditions and alerts, and monitor any ADIC (Quantum) storage products from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.3764adicADIC-INTELLIGENT-STORAGE-MIB
1.3.6.1.4.1.3764.1storageADIC-INTELLIGENT-STORAGE-MIB
1.3.6.1.4.1.3764.1.1intelligentADIC-INTELLIGENT-STORAGE-MIB
1.3.6.1.4.1.3764.1.1.200hardwareADIC-INTELLIGENT-STORAGE-MIB
1.3.6.1.4.1.3764.1.1.200.200powerAndCoolingADIC-INTELLIGENT-STORAGE-MIB
1.3.6.1.4.1.3764.1.1.200.200.30temperatureSensorTableADIC-INTELLIGENT-STORAGE-MIB
1.3.6.1.4.1.3764.1.1.200.200.30.1temperatureSensorEntryADIC-INTELLIGENT-STORAGE-MIB
1.3.6.1.4.1.3764.1.1.200.200.30.1.7temperatureSensorWarningLoADIC-INTELLIGENT-STORAGE-MIB