All MIBs › ADIC-INTELLIGENT-STORAGE-MIB › temperatureSensorWarningHi
temperatureSensorWarningHi
Module: ADIC-INTELLIGENT-STORAGE-MIB
OID (symbolic): ADIC-INTELLIGENT-STORAGE-MIB::temperatureSensorWarningHi
OID (numeric): 1.3.6.1.4.1.3764.1.1.200.200.30.1.8
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: ** This object is optional ** Upper temperature limit of the warning state for this temperature sensor. Unit are degrees Celsius. If the temperature rises above this limit, the sensor enters the alarm state.
What is temperatureSensorWarningHi?
This OID stores the upper temperature limit (in degrees Celsius) at which the sensor enters a warning state. Engineers set this to prevent equipment from overheating and damaging hardware components. For example, a threshold of 45°C will trigger an alert if the monitored device exceeds this temperature, giving the team time to cool the system before critical damage occurs.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3764.1.1.200.200.30.1.8 snmpwalk -v2c -c public <target> ADIC-INTELLIGENT-STORAGE-MIB::temperatureSensorWarningHi
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.3764.1.1.200.200.30.1.8.1 snmpget -v2c -c public <target> ADIC-INTELLIGENT-STORAGE-MIB::temperatureSensorWarningHi.1
Start monitoring ADIC (Quantum) storage products with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADIC-INTELLIGENT-STORAGE-MIB::temperatureSensorWarningHi OID value, configure state conditions and alerts, and monitor any ADIC (Quantum) storage products from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.3764 | adic | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1 | storage | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1 | intelligent | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1.200 | hardware | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1.200.200 | powerAndCooling | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1.200.200.30 | temperatureSensorTable | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1.200.200.30.1 | temperatureSensorEntry | ADIC-INTELLIGENT-STORAGE-MIB |