All MIBs › ADIC-INTELLIGENT-STORAGE-MIB › temperatureSensorStatus
temperatureSensorStatus
Module: ADIC-INTELLIGENT-STORAGE-MIB
OID (symbolic): ADIC-INTELLIGENT-STORAGE-MIB::temperatureSensorStatus
OID (numeric): 1.3.6.1.4.1.3764.1.1.200.200.30.1.3
Node type: OBJECT-TYPE
Type: AdicSensorStatus
Access: read-only
Description: ** This object is optional ** What is the state of this temperatureSensor? Is the temperature in the nominal, warning or alarm region?
What is temperatureSensorStatus?
This OID reports the current thermal health state as nominal (safe), warning (elevated but tolerable), or alarm (critical and dangerous). A network engineer builds monitoring dashboards around this value to detect cooling failures or thermal throttling before they cause service degradation or component failure. For example, a status of 'warning' indicates the temperature is creeping above safe limits and cooling needs investigation.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3764.1.1.200.200.30.1.3 snmpwalk -v2c -c public <target> ADIC-INTELLIGENT-STORAGE-MIB::temperatureSensorStatus
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.3764.1.1.200.200.30.1.3.1 snmpget -v2c -c public <target> ADIC-INTELLIGENT-STORAGE-MIB::temperatureSensorStatus.1
Start monitoring ADIC (Quantum) storage products with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADIC-INTELLIGENT-STORAGE-MIB::temperatureSensorStatus OID value, configure state conditions and alerts, and monitor any ADIC (Quantum) storage products from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.3764 | adic | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1 | storage | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1 | intelligent | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1.200 | hardware | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1.200.200 | powerAndCooling | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1.200.200.30 | temperatureSensorTable | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1.200.200.30.1 | temperatureSensorEntry | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1.200.200.30.1.3 | temperatureSensorStatus | ADIC-INTELLIGENT-STORAGE-MIB |