ADIC-INTELLIGENT-STORAGE-MIB :: temperatureSensorDegreesCelsius

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADIC-INTELLIGENT-STORAGE-MIBtemperatureSensorDegreesCelsius

temperatureSensorDegreesCelsius

Module: ADIC-INTELLIGENT-STORAGE-MIB

OID (symbolic): ADIC-INTELLIGENT-STORAGE-MIB::temperatureSensorDegreesCelsius

OID (numeric): 1.3.6.1.4.1.3764.1.1.200.200.30.1.4

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: ** This object is optional ** The temperature in degrees Celsuis for this temperature sensor.

What is temperatureSensorDegreesCelsius?

This OID provides the real-time temperature reading in degrees Celsius from a specific location in the storage device. A network engineer continuously monitors this value to detect cooling system failures, blocked air ducts, or capacity limits that need addressing. For example, a value of 62 indicates the sensor is reading 62 degrees Celsius, which might be normal or concerning depending on the device type and thresholds.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3764.1.1.200.200.30.1.4
snmpwalk -v2c -c public <target> ADIC-INTELLIGENT-STORAGE-MIB::temperatureSensorDegreesCelsius

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.3764.1.1.200.200.30.1.4.1
snmpget -v2c -c public <target> ADIC-INTELLIGENT-STORAGE-MIB::temperatureSensorDegreesCelsius.1

Start monitoring ADIC (Quantum) storage products with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADIC-INTELLIGENT-STORAGE-MIB::temperatureSensorDegreesCelsius OID value, configure state conditions and alerts, and monitor any ADIC (Quantum) storage products from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.3764adicADIC-INTELLIGENT-STORAGE-MIB
1.3.6.1.4.1.3764.1storageADIC-INTELLIGENT-STORAGE-MIB
1.3.6.1.4.1.3764.1.1intelligentADIC-INTELLIGENT-STORAGE-MIB
1.3.6.1.4.1.3764.1.1.200hardwareADIC-INTELLIGENT-STORAGE-MIB
1.3.6.1.4.1.3764.1.1.200.200powerAndCoolingADIC-INTELLIGENT-STORAGE-MIB
1.3.6.1.4.1.3764.1.1.200.200.30temperatureSensorTableADIC-INTELLIGENT-STORAGE-MIB
1.3.6.1.4.1.3764.1.1.200.200.30.1temperatureSensorEntryADIC-INTELLIGENT-STORAGE-MIB
1.3.6.1.4.1.3764.1.1.200.200.30.1.4temperatureSensorDegreesCelsiusADIC-INTELLIGENT-STORAGE-MIB