ADIC-INTELLIGENT-STORAGE-MIB :: powerSupplyRatedVoltage

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADIC-INTELLIGENT-STORAGE-MIBpowerSupplyRatedVoltage

powerSupplyRatedVoltage

Module: ADIC-INTELLIGENT-STORAGE-MIB

OID (symbolic): ADIC-INTELLIGENT-STORAGE-MIB::powerSupplyRatedVoltage

OID (numeric): 1.3.6.1.4.1.3764.1.1.200.200.10.1.6

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: ** This object is optional ** Rated output voltage in millivolts of this power supply.

What is powerSupplyRatedVoltage?

This OID reports the maximum output voltage this power supply is designed to deliver, measured in millivolts (typically 5000-12000 mV). A network engineer uses this during system commissioning and troubleshooting to verify that the installed power supply matches the equipment specification and operating requirements. For example, a value of 12000 indicates a 12-volt power supply, which must match the device's voltage requirements.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3764.1.1.200.200.10.1.6
snmpwalk -v2c -c public <target> ADIC-INTELLIGENT-STORAGE-MIB::powerSupplyRatedVoltage

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.3764.1.1.200.200.10.1.6.1
snmpget -v2c -c public <target> ADIC-INTELLIGENT-STORAGE-MIB::powerSupplyRatedVoltage.1

Start monitoring ADIC (Quantum) storage products with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADIC-INTELLIGENT-STORAGE-MIB::powerSupplyRatedVoltage OID value, configure state conditions and alerts, and monitor any ADIC (Quantum) storage products from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.3764adicADIC-INTELLIGENT-STORAGE-MIB
1.3.6.1.4.1.3764.1storageADIC-INTELLIGENT-STORAGE-MIB
1.3.6.1.4.1.3764.1.1intelligentADIC-INTELLIGENT-STORAGE-MIB
1.3.6.1.4.1.3764.1.1.200hardwareADIC-INTELLIGENT-STORAGE-MIB
1.3.6.1.4.1.3764.1.1.200.200powerAndCoolingADIC-INTELLIGENT-STORAGE-MIB
1.3.6.1.4.1.3764.1.1.200.200.10powerSupplyTableADIC-INTELLIGENT-STORAGE-MIB
1.3.6.1.4.1.3764.1.1.200.200.10.1powerSupplyEntryADIC-INTELLIGENT-STORAGE-MIB
1.3.6.1.4.1.3764.1.1.200.200.10.1.6powerSupplyRatedVoltageADIC-INTELLIGENT-STORAGE-MIB