All MIBs › ADIC-INTELLIGENT-STORAGE-MIB › coolingFanWarningLo
coolingFanWarningLo
Module: ADIC-INTELLIGENT-STORAGE-MIB
OID (symbolic): ADIC-INTELLIGENT-STORAGE-MIB::coolingFanWarningLo
OID (numeric): 1.3.6.1.4.1.3764.1.1.200.200.40.1.7
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: ** This object is optional ** Lower fan speed limit of the warning state for this fan. Units are RPM. If the speed falls below this limit, the fan enters the alarmLow state.
What is coolingFanWarningLo?
This OID stores the speed threshold below which the fan generates a warning alert (still above alarm). Engineers set this to be notified of slow fans before they fail completely. For example, a value of 1500 RPM triggers a warning, giving the team time to plan maintenance before the fan drops into the critical alarm range.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3764.1.1.200.200.40.1.7 snmpwalk -v2c -c public <target> ADIC-INTELLIGENT-STORAGE-MIB::coolingFanWarningLo
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.3764.1.1.200.200.40.1.7.1 snmpget -v2c -c public <target> ADIC-INTELLIGENT-STORAGE-MIB::coolingFanWarningLo.1
Start monitoring ADIC (Quantum) storage products with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADIC-INTELLIGENT-STORAGE-MIB::coolingFanWarningLo OID value, configure state conditions and alerts, and monitor any ADIC (Quantum) storage products from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.3764 | adic | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1 | storage | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1 | intelligent | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1.200 | hardware | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1.200.200 | powerAndCooling | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1.200.200.40 | coolingFanTable | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1.200.200.40.1 | coolingFanEntry | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1.200.200.40.1.7 | coolingFanWarningLo | ADIC-INTELLIGENT-STORAGE-MIB |