Description: ** This object is optional ** Lower fan speed limit of the nominal state for this fan. Units are RPM.
What is coolingFanNominalLo?
This OID stores the minimum RPM at which the fan is considered to be operating normally. Engineers reference this to understand the expected baseline behavior of a healthy fan. For example, a threshold of 2000 RPM means the fan should never drop below this speed during normal operation.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3764.1.1.200.200.40.1.5 snmpwalk -v2c -c public <target> ADIC-INTELLIGENT-STORAGE-MIB::coolingFanNominalLo
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.3764.1.1.200.200.40.1.5.1 snmpget -v2c -c public <target> ADIC-INTELLIGENT-STORAGE-MIB::coolingFanNominalLo.1
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> coolingFanNominalLo.1
Start monitoring ADIC (Quantum) storage products with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADIC-INTELLIGENT-STORAGE-MIB::coolingFanNominalLo OID value, configure state conditions and alerts, and monitor any ADIC (Quantum) storage products from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.3764 | adic | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1 | storage | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1 | intelligent | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1.200 | hardware | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1.200.200 | powerAndCooling | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1.200.200.40 | coolingFanTable | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1.200.200.40.1 | coolingFanEntry | ADIC-INTELLIGENT-STORAGE-MIB |
| 1.3.6.1.4.1.3764.1.1.200.200.40.1.5 | coolingFanNominalLo | ADIC-INTELLIGENT-STORAGE-MIB |