ADIC-INTELLIGENT-STORAGE-MIB :: coolingFanNominalHi

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADIC-INTELLIGENT-STORAGE-MIBcoolingFanNominalHi

coolingFanNominalHi

Module: ADIC-INTELLIGENT-STORAGE-MIB

OID (symbolic): ADIC-INTELLIGENT-STORAGE-MIB::coolingFanNominalHi

OID (numeric): 1.3.6.1.4.1.3764.1.1.200.200.40.1.6

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: ** This object is optional ** Upper fan speed limit of the nominal state for this fan. Units are RPM.

What is coolingFanNominalHi?

This OID stores the maximum RPM for normal fan operation without triggering any alarms. Engineers use this to establish performance expectations for the cooling system. For example, a setting of 5500 RPM means the fan should stay below this speed during regular operation.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3764.1.1.200.200.40.1.6
snmpwalk -v2c -c public <target> ADIC-INTELLIGENT-STORAGE-MIB::coolingFanNominalHi

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.3764.1.1.200.200.40.1.6.1
snmpget -v2c -c public <target> ADIC-INTELLIGENT-STORAGE-MIB::coolingFanNominalHi.1

Start monitoring ADIC (Quantum) storage products with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADIC-INTELLIGENT-STORAGE-MIB::coolingFanNominalHi OID value, configure state conditions and alerts, and monitor any ADIC (Quantum) storage products from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.3764adicADIC-INTELLIGENT-STORAGE-MIB
1.3.6.1.4.1.3764.1storageADIC-INTELLIGENT-STORAGE-MIB
1.3.6.1.4.1.3764.1.1intelligentADIC-INTELLIGENT-STORAGE-MIB
1.3.6.1.4.1.3764.1.1.200hardwareADIC-INTELLIGENT-STORAGE-MIB
1.3.6.1.4.1.3764.1.1.200.200powerAndCoolingADIC-INTELLIGENT-STORAGE-MIB
1.3.6.1.4.1.3764.1.1.200.200.40coolingFanTableADIC-INTELLIGENT-STORAGE-MIB
1.3.6.1.4.1.3764.1.1.200.200.40.1coolingFanEntryADIC-INTELLIGENT-STORAGE-MIB
1.3.6.1.4.1.3764.1.1.200.200.40.1.6coolingFanNominalHiADIC-INTELLIGENT-STORAGE-MIB