ACMEPACKET-ENVMON-MIB :: apEnvMonFanStatusValue

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsACMEPACKET-ENVMON-MIBapEnvMonFanStatusValue

apEnvMonFanStatusValue

Module: ACMEPACKET-ENVMON-MIB

OID (symbolic): ACMEPACKET-ENVMON-MIB::apEnvMonFanStatusValue

OID (numeric): 1.3.6.1.4.1.9148.3.3.1.4.1.1.4

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: The current percentage measurement of the fan speed.

What is apEnvMonFanStatusValue?

This OID reports the current fan speed as a percentage of maximum RPM (0-100%), helping administrators detect when cooling is degraded. Engineers monitor this to ensure adequate airflow is being maintained and to receive warnings before the device overheats due to slow or failed fans. For example, a fan speed reading of 100% indicates the fan is running at full capacity, which may signal that the device needs more cooling than the normal operating point.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9148.3.3.1.4.1.1.4
snmpwalk -v2c -c public <target> ACMEPACKET-ENVMON-MIB::apEnvMonFanStatusValue

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9148.3.3.1.4.1.1.4.1
snmpget -v2c -c public <target> ACMEPACKET-ENVMON-MIB::apEnvMonFanStatusValue.1

Start monitoring Oracle Acme Packet SBCs with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ACMEPACKET-ENVMON-MIB::apEnvMonFanStatusValue OID value, configure state conditions and alerts, and monitor any Oracle Acme Packet SBCs from a single console.

How to Use in IPNetwork Monitor

Select an Oracle Acme Packet SBC as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type apEnvMonFanStatusValue into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The current percentage measurement of the fan speed. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Gauge32-type OID, Value bounds is the most useful condition here — trigger an alert if the speed drops below the level expected for a healthy, spinning fan, since a stalled or slowing fan often precedes overheating. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9148acmepacketACMEPACKET-SMI
1.3.6.1.4.1.9148.3acmepacketMgmtACMEPACKET-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9148.3.3apEnvMonModuleACMEPACKET-ENVMON-MIB
1.3.6.1.4.1.9148.3.3.1apEnvMonObjectsACMEPACKET-ENVMON-MIB
1.3.6.1.4.1.9148.3.3.1.4apEnvMonFanObjectsACMEPACKET-ENVMON-MIB
1.3.6.1.4.1.9148.3.3.1.4.1apEnvMonFanStatusTableACMEPACKET-ENVMON-MIB
1.3.6.1.4.1.9148.3.3.1.4.1.1apEnvMonFanStatusEntryACMEPACKET-ENVMON-MIB
1.3.6.1.4.1.9148.3.3.1.4.1.1.4apEnvMonFanStatusValueACMEPACKET-ENVMON-MIB