ACE20-MIB :: atmSuPortAtmRxClp0Cells

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsACE20-MIBatmSuPortAtmRxClp0Cells

atmSuPortAtmRxClp0Cells

Module: ACE20-MIB

OID (symbolic): ACE20-MIB::atmSuPortAtmRxClp0Cells

OID (numeric): 1.3.6.1.4.1.164.12.4.2.3.2.1.1

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: The number of cells received with correct HECs and CLP=0 and not misrouted

What is atmSuPortAtmRxClp0Cells?

This counter reports how many high-priority (CLP=0) ATM cells have arrived with valid checksums and correct routing. Network engineers monitor this to verify that critical traffic is arriving successfully and to detect unexpected packet loss. For example, a steadily increasing value like 50,000,000 cells shows the port is receiving high-priority traffic correctly; a sudden halt indicates a problem.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.164.12.4.2.3.2.1.1
snmpwalk -v2c -c public <target> ACE20-MIB::atmSuPortAtmRxClp0Cells

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.164.12.4.2.3.2.1.1.1
snmpget -v2c -c public <target> ACE20-MIB::atmSuPortAtmRxClp0Cells.1

Start monitoring Nortel ACE 20 ATM concentrator (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ACE20-MIB::atmSuPortAtmRxClp0Cells OID value, configure state conditions and alerts, and monitor any Nortel ACE 20 ATM concentrator (legacy) from a single console.

How to Use in IPNetwork Monitor

Select a Nortel ACE 20 ATM concentrator (legacy) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type atmSuPortAtmRxClp0Cells into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The number of cells received with correct HECs and CLP=0 and not misrouted. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.164radDACS-MIB
1.3.6.1.4.1.164.12radAtmRAD-MIB
Numeric OIDNameModule
1.3.6.1.4.1.164.12.4atmSuACE20-MIB
1.3.6.1.4.1.164.12.4.2atmSuPortACE20-MIB
1.3.6.1.4.1.164.12.4.2.3atmSuPortAtmACE20-MIB
1.3.6.1.4.1.164.12.4.2.3.2atmSuPortAtmIfStatsTableACE20-MIB
1.3.6.1.4.1.164.12.4.2.3.2.1atmSuPortAtmIfStatsEntryACE20-MIB
1.3.6.1.4.1.164.12.4.2.3.2.1.1atmSuPortAtmRxClp0CellsACE20-MIB