ACD-SFP-MIB :: acdSfpThreshStatusLbcHighAlm

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsACD-SFP-MIBacdSfpThreshStatusLbcHighAlm

acdSfpThreshStatusLbcHighAlm

Module: ACD-SFP-MIB

OID (symbolic): ACD-SFP-MIB::acdSfpThreshStatusLbcHighAlm

OID (numeric): 1.3.6.1.4.1.22420.2.4.4.1.11

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-only

Description: This is to indicate if the Laser Bias Current reaches or overpasses the High alarm threshold.

What is acdSfpThreshStatusLbcHighAlm?

This OID returns true/false to indicate if the SFP laser's bias current has exceeded the high alarm threshold, signaling possible laser degradation or failure. Excessive bias current causes the laser to age rapidly and eventually fail, reducing module lifespan from years to months. A true alarm value means the laser is drawing too much current—for example, 100 mA when the alarm is 95 mA—and should be replaced soon.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.22420.2.4.4.1.11
snmpwalk -v2c -c public <target> ACD-SFP-MIB::acdSfpThreshStatusLbcHighAlm

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.22420.2.4.4.1.11.1
snmpget -v2c -c public <target> ACD-SFP-MIB::acdSfpThreshStatusLbcHighAlm.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> acdSfpThreshStatusLbcHighAlm.1

Start monitoring Accedian MetroNID devices with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ACD-SFP-MIB::acdSfpThreshStatusLbcHighAlm OID value, configure state conditions and alerts, and monitor any Accedian MetroNID devices from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.22420accedianMIBACCEDIAN-SMI
1.3.6.1.4.1.22420.2acdMibsACCEDIAN-SMI
Numeric OIDNameModule
1.3.6.1.4.1.22420.2.4acdSfpACD-SFP-MIB
1.3.6.1.4.1.22420.2.4.4acdSfpThreshStatusTableACD-SFP-MIB
1.3.6.1.4.1.22420.2.4.4.1acdSfpThreshStatusEntryACD-SFP-MIB
1.3.6.1.4.1.22420.2.4.4.1.11acdSfpThreshStatusLbcHighAlmACD-SFP-MIB