ACD-ERP-MIB :: acdErpConfigRevertive

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsACD-ERP-MIBacdErpConfigRevertive

acdErpConfigRevertive

Module: ACD-ERP-MIB

OID (symbolic): ACD-ERP-MIB::acdErpConfigRevertive

OID (numeric): 1.3.6.1.4.1.22420.2.15.0.1.1.1.7

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-write

Description: This indicates if the ERP is in revertive state.

What is acdErpConfigRevertive?

Controls whether the ring automatically reverts to its original configuration after a fault clears (true) or stays in failover mode (false). Network engineers enable this to restore normal traffic paths when a failed link recovers, or disable it if they want the backup path to remain active. If set to true and the original RPL port comes back online, the ring automatically reverts.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.22420.2.15.0.1.1.1.7
snmpwalk -v2c -c public <target> ACD-ERP-MIB::acdErpConfigRevertive

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.22420.2.15.0.1.1.1.7.1
snmpget -v2c -c public <target> ACD-ERP-MIB::acdErpConfigRevertive.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.22420.2.15.0.1.1.1.7.1 s <value>

Start monitoring Accedian MetroNID devices with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ACD-ERP-MIB::acdErpConfigRevertive OID value, configure state conditions and alerts, and monitor any Accedian MetroNID devices from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.22420accedianMIBACCEDIAN-SMI
1.3.6.1.4.1.22420.2acdMibsACCEDIAN-SMI
Numeric OIDNameModule
1.3.6.1.4.1.22420.2.15acdErpACD-ERP-MIB
1.3.6.1.4.1.22420.2.15.0acdErpMIBObjectsACD-ERP-MIB
1.3.6.1.4.1.22420.2.15.0.1acdErpConfigACD-ERP-MIB
1.3.6.1.4.1.22420.2.15.0.1.1acdErpConfigTableACD-ERP-MIB
1.3.6.1.4.1.22420.2.15.0.1.1.1acdErpConfigEntryACD-ERP-MIB
1.3.6.1.4.1.22420.2.15.0.1.1.1.7acdErpConfigRevertiveACD-ERP-MIB