All MIBs › ACD-ALARM-MIB › acdAlarmCfgNumber
acdAlarmCfgNumber
Module: ACD-ALARM-MIB
OID (symbolic): ACD-ALARM-MIB::acdAlarmCfgNumber
OID (numeric): 1.3.6.1.4.1.22420.2.1.10.1.2
Node type: OBJECT-TYPE
Type: Unsigned32
Access: read-only
Description: Unique number that identifies this alarm. Assigned by the unit. The alarm identifier is compose of 3 fields, the module number, the instance number and the error number. The alarm number looks like this: A.BBB.CC and is expressed in decimal, A is the module number, BBB is the instance number (1-999) and CC is the error number (1-99). A module number is assigned for each source of alarm in the system. For example the port module is set to 1, the SFP module is set to 2, the PAA is set to 3 and the environmental is set to 8.
What is acdAlarmCfgNumber?
This OID displays the device-assigned alarm number encoded in a hierarchical format (module.instance.error) that identifies where an alarm originates within the equipment. You use this number to look up the alarm's cause in the device documentation and understand which component or function is affected. An alarm number like 1.007.05 means module 1 (power supply), instance 7, error code 05 (overvoltage condition).
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.22420.2.1.10.1.2 snmpwalk -v2c -c public <target> ACD-ALARM-MIB::acdAlarmCfgNumber
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.22420.2.1.10.1.2.1 snmpget -v2c -c public <target> ACD-ALARM-MIB::acdAlarmCfgNumber.1
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> acdAlarmCfgNumber.1
Start monitoring Accedian MetroNID devices with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ACD-ALARM-MIB::acdAlarmCfgNumber OID value, configure state conditions and alerts, and monitor any Accedian MetroNID devices from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.22420 | accedianMIB | ACCEDIAN-SMI |
| 1.3.6.1.4.1.22420.2 | acdMibs | ACCEDIAN-SMI |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.22420.2.1 | acdAlarm | ACD-ALARM-MIB |
| 1.3.6.1.4.1.22420.2.1.10 | acdAlarmCfgTable | ACD-ALARM-MIB |
| 1.3.6.1.4.1.22420.2.1.10.1 | acdAlarmCfgEntry | ACD-ALARM-MIB |
| 1.3.6.1.4.1.22420.2.1.10.1.2 | acdAlarmCfgNumber | ACD-ALARM-MIB |