ACC-SLOT :: accRmFanStatTrap

MIB Reference — IPNetwork Monitor

All MIBsACC-SLOTaccRmFanStatTrap

accRmFanStatTrap

Module: ACC-SLOT

OID (symbolic): ACC-SLOT::accRmFanStatTrap

OID (numeric): 1.3.6.1.4.1.5.1.1.5.6.0.26

Node type: NOTIFICATION-TYPE

Description:

If the fan in the TIGRIS power supply fails or receovered this trap is generated. SEVERITY-VARIABLE: accTrapLogSeverityType EVENTTYPE-DEFAULT: 4 ADDITIONAL-TEXT-VARIABLES: { accTrapLogSeqNum,accCardSlotTrapMsg } PCAUSE-DEFAULT: 207

Examples

Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):

snmptrap -v2c -c public <manager> '' ACC-SLOT::accRmFanStatTrap
snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.5.1.1.5.6.0.26

Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):

snmptrapd -f -Lo -c /dev/null authCommunity log public

Example snmptrapd log entry:

zoo11-linux.zoo [UDP: [192.168.30.111]:60654->[192.168.30.10]:162]:
  DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (420257518) 48 days, 15:22:55.18
  SNMPv2-MIB::snmpTrapOID.0 = OID: ACC-SLOT::accRmFanStatTrap

OID Breakdown

Numeric OIDNameModule
1isoLANART-AGENT
1.3orgBIANCA-BRICK-PPP-MIB
1.3.6dodBIANCA-BRICK-PPP-MIB
1.3.6.1internetBIANCA-BRICK-PPP-MIB
1.3.6.1.4privateBIANCA-BRICK-PPP-MIB
1.3.6.1.4.1enterprisesANIROOT-MIB
1.3.6.1.4.1.5accACC-MIB
1.3.6.1.4.1.5.1accSBARACC-MIB
1.3.6.1.4.1.5.1.1accBRGACC-MIB
1.3.6.1.4.1.5.1.1.5accSlotACC-MIB
1.3.6.1.4.1.5.1.1.5.6accCardSlotTrapsACC-SLOT
1.3.6.1.4.1.5.1.1.5.6.0.26accRmFanStatTrapACC-SLOT