ZYXEL-accessSwitch-MIB :: accessSwitchSysTempHighThresh

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsZYXEL-accessSwitch-MIBaccessSwitchSysTempHighThresh

accessSwitchSysTempHighThresh

Module: ZYXEL-accessSwitch-MIB

OID (symbolic): ZYXEL-accessSwitch-MIB::accessSwitchSysTempHighThresh

OID (numeric): 1.3.6.1.4.1.890.1.5.1.1.6.1.5

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The high threshold of the temperature in Celsius. If the current temperature is higher than the threshold, the device will initiate the overheat trap.

What is accessSwitchSysTempHighThresh?

This read-only INTEGER sets the high temperature threshold, in Celsius, for a system sensor; per the DESCRIPTION, if the current temperature exceeds this value the device raises an overheat trap. An admin reads this to know at what temperature a given monitored point is considered overheating and will trigger an alert. If accessSwitchSysTempCurValue exceeds this threshold, an admin should expect an overheat trap and a corresponding sysOverHeat bit set in accessSwitchSystemCurrentStatus.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.890.1.5.1.1.6.1.5
snmpwalk -v2c -c public <target> ZYXEL-accessSwitch-MIB::accessSwitchSysTempHighThresh

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.890.1.5.1.1.6.1.5.1
snmpget -v2c -c public <target> ZYXEL-accessSwitch-MIB::accessSwitchSysTempHighThresh.1

Start monitoring ZyXEL access switch (port/subscriber-line operational status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ZYXEL-accessSwitch-MIB::accessSwitchSysTempHighThresh OID value, configure state conditions and alerts, and monitor any ZyXEL access switch (port/subscriber-line operational status) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.890zyxelNWA1100
1.3.6.1.4.1.890.1nwaSeriesNWA1100
Numeric OIDNameModule
1.3.6.1.4.1.890.1.5accessSwitchZYXEL-accessSwitch-MIB
1.3.6.1.4.1.890.1.5.1accessSwitchCommonZYXEL-accessSwitch-MIB
1.3.6.1.4.1.890.1.5.1.1accessSwitchMgntZYXEL-accessSwitch-MIB
1.3.6.1.4.1.890.1.5.1.1.6accessSwitchSysTempTableZYXEL-accessSwitch-MIB
1.3.6.1.4.1.890.1.5.1.1.6.1accessSwitchSysTempEntryZYXEL-accessSwitch-MIB
1.3.6.1.4.1.890.1.5.1.1.6.1.5accessSwitchSysTempHighThreshZYXEL-accessSwitch-MIB