tempIndex

Module: ZYXEL-ES3124PWR-MIB

OID (symbolic): ZYXEL-ES3124PWR-MIB::tempIndex

OID (numeric): 1.3.6.1.4.1.890.1.5.8.14.9.2.1.1

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Index of temperature unit. 1:MAC, 2:CPU, 3:PHY

What is tempIndex?

Identifies which temperature sensor a row refers to; per the source SYNTAX, 1=MAC, 2=CPU, 3=PHY, letting an admin tell which chip is running hot.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.890.1.5.8.14.9.2.1.1
snmpwalk -v2c -c public <target> ZYXEL-ES3124PWR-MIB::tempIndex

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.890.1.5.8.14.9.2.1.1.1
snmpget -v2c -c public <target> ZYXEL-ES3124PWR-MIB::tempIndex.1

Start monitoring ZyXEL PoE switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ZYXEL-ES3124PWR-MIB::tempIndex OID value, configure state conditions and alerts, and monitor any ZyXEL PoE switches from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.890zyxelIES5206-MIB
1.3.6.1.4.1.890.1productsIES5206-MIB
1.3.6.1.4.1.890.1.5accessSwitchIES5206-MIB
1.3.6.1.4.1.890.1.5.8esSeriesZYXEL-ES2024A-MIB
Numeric OIDNameModule
1.3.6.1.4.1.890.1.5.8.14es3124pwrZYXEL-ES3124PWR-MIB
1.3.6.1.4.1.890.1.5.8.14.9hwMonitorInfoZYXEL-ES3124PWR-MIB
1.3.6.1.4.1.890.1.5.8.14.9.2tempTableZYXEL-ES3124PWR-MIB
1.3.6.1.4.1.890.1.5.8.14.9.2.1tempEntryZYXEL-ES3124PWR-MIB
1.3.6.1.4.1.890.1.5.8.14.9.2.1.1tempIndexZYXEL-ES3124PWR-MIB