ZTE-AN-CLOCK-MIB :: zxAnClockWaitToRestoreTime

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › ZTE-AN-CLOCK-MIB › zxAnClockWaitToRestoreTime

zxAnClockWaitToRestoreTime

Module: ZTE-AN-CLOCK-MIB

OID (symbolic): ZTE-AN-CLOCK-MIB::zxAnClockWaitToRestoreTime

OID (numeric): 1.3.6.1.4.1.3902.1082.120.10.1.4

Node type: OBJECT-TYPE

Type: Integer32

Access: read-write

Description: This attribute specifies the clock source wait to restore time, comply with G.781 section 5.9 wait to restore time.

What is zxAnClockWaitToRestoreTime?

Sets, in minutes (0-12, default 5), how long a higher-priority clock source must remain stable before the system switches back to it, per ITU-T G.781's wait-to-restore timer; this prevents rapid flapping back and forth when a preferred source is intermittently available.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3902.1082.120.10.1.4
snmpwalk -v2c -c public <target> ZTE-AN-CLOCK-MIB::zxAnClockWaitToRestoreTime

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.3902.1082.120.10.1.4.1
snmpget -v2c -c public <target> ZTE-AN-CLOCK-MIB::zxAnClockWaitToRestoreTime.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.3902.1082.120.10.1.4.1 i <value>

Start monitoring ZTE Access Node equipment (clock-source-selection/synchronization-state status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ZTE-AN-CLOCK-MIB::zxAnClockWaitToRestoreTime OID value, configure state conditions and alerts, and monitor any ZTE Access Node equipment (clock-source-selection/synchronization-state status) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.3902zteDPI-MIB
1.3.6.1.4.1.3902.1082zxAccessNodeZTE-AN-SMI
1.3.6.1.4.1.3902.1082.120zxAnClockSyncZTE-AN-SMI
Numeric OIDNameModule
1.3.6.1.4.1.3902.1082.120.10zxAnClockMibZTE-AN-CLOCK-MIB
1.3.6.1.4.1.3902.1082.120.10.1zxAnClockGlobalObjectsZTE-AN-CLOCK-MIB