XYLAN-FRAME-RELAY-MIB :: frxPortDefaultBridgingServiceNumber

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsXYLAN-FRAME-RELAY-MIBfrxPortDefaultBridgingServiceNumber

frxPortDefaultBridgingServiceNumber

Module: XYLAN-FRAME-RELAY-MIB

OID (symbolic): XYLAN-FRAME-RELAY-MIB::frxPortDefaultBridgingServiceNumber

OID (numeric): 1.3.6.1.4.1.800.2.8.1.1.1.5

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: If non-zero, this is the unique service number which unconfigured Bridging Virtual Circuits are added to if frxPortDefaultBridgingVLAN is non zero (set to a VLAN ID) and frxPortDefaultBridgingGrouping is set to groupVCsIntoOneVport. This allows an unconfigured VC to be added to an existing configured bridging service virtual circuit group.

If zero, then unconfigured VCs will be added to a newly created (dynamic) Briding Service instance (i.e. a new virtual port is created dynamically).

What is frxPortDefaultBridgingServiceNumber?

When non-zero and frxPortDefaultBridgingVLAN is set, this is the specific bridging-service number new unconfigured PVCs get grouped into rather than each spawning its own dynamic bridging service; zero lets each unconfigured PVC create a new dynamic service instead.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.800.2.8.1.1.1.5
snmpwalk -v2c -c public <target> XYLAN-FRAME-RELAY-MIB::frxPortDefaultBridgingServiceNumber

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.800.2.8.1.1.1.5.1
snmpget -v2c -c public <target> XYLAN-FRAME-RELAY-MIB::frxPortDefaultBridgingServiceNumber.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.800.2.8.1.1.1.5.1 i <value>

Start monitoring Xylan OmniSwitch device (legacy Frame Relay PVC/DLCI admin-status/traffic-shaping config status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the XYLAN-FRAME-RELAY-MIB::frxPortDefaultBridgingServiceNumber OID value, configure state conditions and alerts, and monitor any Xylan OmniSwitch device (legacy Frame Relay PVC/DLCI admin-status/traffic-shaping config status) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.800xylanXYLAN-BASE-MIB
1.3.6.1.4.1.800.2xylanArchXYLAN-BASE-MIB
1.3.6.1.4.1.800.2.8xylanFrArchXYLAN-BASE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.800.2.8.1frxPortGroupXYLAN-FRAME-RELAY-MIB
1.3.6.1.4.1.800.2.8.1.1frxPortTableXYLAN-FRAME-RELAY-MIB
1.3.6.1.4.1.800.2.8.1.1.1frxPortEntryXYLAN-FRAME-RELAY-MIB
1.3.6.1.4.1.800.2.8.1.1.1.5frxPortDefaultBridgingServiceNumberXYLAN-FRAME-RELAY-MIB