XEDIA-DHCP-MIB :: xdhcpRelayIncludeCircuitID

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › XEDIA-DHCP-MIB › xdhcpRelayIncludeCircuitID

xdhcpRelayIncludeCircuitID

Module: XEDIA-DHCP-MIB

OID (symbolic): XEDIA-DHCP-MIB::xdhcpRelayIncludeCircuitID

OID (numeric): 1.3.6.1.4.1.838.3.28.1.1.3

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-write

Description: Whether the relay agent should add the circuit ID of the ATM or frame relay circuit that a DHCP relay request was received to the DHCP relay request. The circuit ID will be added as a agent circuit ID sub-option of a DHCP relay agent information option (option 82) and will be used by the relay agent to forward the reply to the correct circuit.

What is xdhcpRelayIncludeCircuitID?

This TruthValue flag controls whether the relay agent inserts the ATM or frame relay circuit ID of the incoming DHCP request into the relay agent information option (option 82) as an agent circuit ID sub-option. Admins enable it so the DHCP server, and the relay agent itself when forwarding the reply, can identify and route based on which specific circuit a request originated from. Setting it to true adds the originating circuit's ID to each relayed DHCP request, letting the relay agent correctly direct the corresponding reply back down that same circuit.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.838.3.28.1.1.3
snmpwalk -v2c -c public <target> XEDIA-DHCP-MIB::xdhcpRelayIncludeCircuitID

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.838.3.28.1.1.3.1
snmpget -v2c -c public <target> XEDIA-DHCP-MIB::xdhcpRelayIncludeCircuitID.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.838.3.28.1.1.3.1 s <value>

Start monitoring Xedia access routers (Xedia Corp., later acquired by Lucent) (DHCP/BOOTP relay destination request-reply counter status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the XEDIA-DHCP-MIB::xdhcpRelayIncludeCircuitID OID value, configure state conditions and alerts, and monitor any Xedia access routers (Xedia Corp., later acquired by Lucent) (DHCP/BOOTP relay destination request-reply counter status) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.838xediaXEDIA-REG
1.3.6.1.4.1.838.3xediaMibsXEDIA-REG
Numeric OIDNameModule
1.3.6.1.4.1.838.3.28xediaDhcpMIBXEDIA-DHCP-MIB
1.3.6.1.4.1.838.3.28.1xdhcpObjectsXEDIA-DHCP-MIB
1.3.6.1.4.1.838.3.28.1.1xdhcpRelayXEDIA-DHCP-MIB
1.3.6.1.4.1.838.3.28.1.1.3xdhcpRelayIncludeCircuitIDXEDIA-DHCP-MIB