All MIBs › Wellfleet-HARDWARE-MIB › wfHwModIdOpt
wfHwModIdOpt
Module: Wellfleet-HARDWARE-MIB
OID (symbolic): Wellfleet-HARDWARE-MIB::wfHwModIdOpt
OID (numeric): 1.3.6.1.4.1.18.3.1.2.1.2
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: The module identification number.
Port Configurations
HWStat Name Enet Sync Async Token Framer Fiber
------ ------------ ------ -------- ----- ----- ------ -----
1 ENET-1 2 0 0 0 0 0
8 ENET-2 2 0 0 0 0 0
16 SYNC-1 0 4 1 0 0 0
17 SYNC-1[1] 0 4 1 0 0 0
24 T1-1 0 2 1 0 2 0
32 DSE-1 1 2 1 0 0 0
33 DSE-1[1] 1 2 1 0 0 0
40 DST-4/16 0 2 1 1 0 0
41 SST-4/16[1] 0 1 1 1 0 0
42 DST-4 0 2 1 1 0 0
43 SST-4[1] 0 1 1 1 0 0
44 SST-4/16 0 1 1 1 0 0
45 STOK-4/16[3] 0 0 0 1 0 0
46 SST-4 0 1 1 1 0 0
47 STOK-4[3] 0 0 0 1 0 0
48 FLOPPY 0 0 0 0 0 0
56 T1-2 0 2 1 0 2 0
57 T1-2 0 2 1 0 2 0
58 ST1 0 1 1 0 1 0
60 T1-56K 0 1 1 0 1 0
61 E1[3] 0 2 0 0 2 0
62 ST1-56K 0 1 1 0 1 0
63 SE1[3] 0 1 0 0 1 0
64 T1-2n 0 2 1 0 2 0
65 ST1n 0 1 1 0 1 0
66 T1-56Kn 0 1 1 0 1 0
67 ST1-56Kn 0 1 1 0 1 0
68 E1n[3] 0 2 0 0 2 0
69 SE1n[3] 0 1 0 0 1 0
80 SYNC-2 0 4 1 0 0 0
81 SYNC-2[1] 0 4 1 0 0 0
88 CMC-FDDI[6] 0 0 0 0 0 1
89 IPHASE-FDDI[6] 0 0 0 0 0 1
112 DSDE-1 2 2 1 0 0 0
113 DSDE-1[1] 2 2 1 0 0 0
114 ENET 2 0 0 0 0 0
116 DSE-2 1 2 1 0 0 0
117 DSE-2[1] 1 2 1 0 0 0
118 SSE 1 1 1 0 0 0
119 SSE[1] 1 1 1 0 0 0
132 ENET-3[2] 2 0 0 0 0 0
156 DSDE-2[2] 2 2 1 0 0 0
160 QE/NF 4 0 0 0 0 0
161 DE/NF[5] 2 0 0 0 0 0
162 QE/NF 4 0 0 0 0 0
164 QE/F[4] 4 0 0 0 0 0
165 DE/F[4,5] 2 0 0 0 0 0
168 MCT1 0 2 Munich 0 0 2 0
169 SMCT1 0 1 Munich 0 0 1 0
176 DTOK 0 0 0 2 0 0
184 MCE1 0 2 Munich 0 0 2 0
185 SMCE1 0 1 Munich 0 0 1 0
188 MCE1II75 0 2 Munich 0 0 2 0
189 SMCE1II75 0 1 Munich 0 0 1 0
190 MCE1II120 0 2 Munich 0 0 2 0
191 SMCE1II120 0 1 Munich 0 0 1 0
192 WF_FDDI_2M 0 0 0 0 0 1
193 WF_FDDI_1M 0 0 0 0 0 1
194 WF_FDDI_2S 0 0 0 0 0 1
195 WF_FDDI_1S 0 0 0 0 0 1
196 WF_FDDI_2MF 0 0 0 0 0 1
197 WF_FDDI_1MF 0 0 0 0 0 1
198 WF_FDDI_2SF 0 0 0 0 0 1
199 WF_FDDI_1SF 0 0 0 0 0 1
200 HW_MODULE_FMDSET[7] 1 2 0 1 0 0
201 HW_MODULE_FMDST[7] 0 2 0 1 0 0
202 HW_MODULE_FMDSE[7] 1 2 0 0 0 0
203 HW_MODULE_FMSST[7] 0 1 0 1 0 0
204 HW_MODULE_FMSSE[7] 1 1 0 0 0 0
208 FNSDSE[7] 1 2 0 0 0 0
216 FNSDSDT[7] 0 2 0 2 0 0
217 FNSDST[7] 0 2 0 1 0 0
224 DHSSI 0 2 hssi 0 0 0 0
225 SHSSI 0 1 hssi 0 0 0 0
232 ESAF_NF 2 2 0 0 0 0
233 ESAF_DSE_NF 1 2 0 0 0 0
234 ESAF_SSE_NF 1 1 0 0 0 0
235 ESAF_DE_NF 2 0 0 0 0 0
236 ESAF[2] 2 2 0 0 0 0
237 ESAF_DSE[2] 1 2 0 0 0 0
238 ESAF_SSE[2] 1 1 0 0 0 0
239 ESAF_DE[2] 2 0 0 0 0 0
256 QTOK 0 0 0 4 0 0
511 ASN[8] ASN (Barracuda)
513 SN[12] SN (Fiddlestix)
767 ARN[11] ARN (Neptune)
777 FBR[13] FBR (Orion)
778 FBRCARRIER[14] FBR Carrier Card (Orion)
787 LITE LITE (Valkyrie)
AN Module IDs (Piranha, Guppy...)
ID Mnemonic ENET SYNC ISDN TR HUB DCM
-- -------- ---- ---- ---- -- --- ---
1024 ANSEDS 1 2 0 0 0 N
1025 ANSEDST 1 2 0 1 0 N
1026 ANSEDSH 1 2 0 0 12 N
1027 ANSEDSI 1 2 1 0 0 N
1028 ANSEDSTI 1 2 1 1 0 N
1029 ANSEDSHI 1 2 1 0 12 N
1030 ANSETS 1 3 0 0 0 N
1031 ANSETST 1 3 0 1 0 N
1032 ANSETSH 1 3 0 0 12 N
1033 ANDEDS 2 2 0 0 0 N
1034 ANDEDST 2 2 0 1 0 N
1035 ANDEDSH 2 2 0 0 12 N
1036 ANDSTX 0 2 0 1 0 Y
(formerly ANDS)
1037 ANDST 0 2 0 1 0 N
1038 ANDSTI 0 2 1 1 0 N
1039 ANTST 0 3 0 1 0 N
1040 ANTSTX 0 3 0 1 0 Y
(formerly ANSDSEDS)
1041 ANSDSEDST 1 2 0 1 0 N
1042 ANSDSEDSTX 1 2 0 1 0 Y
(formerly ANSDSEDSH)
1043 ANSEDSI2 1 2 1 0 0 N
1044 ANSEDSTI2 1 2 1 1 0 N
1045 ANSEDSHI2 1 2 1 0 12 N
1046 ANDSTI2 0 2 1 1 0 N
1047 ANSEDSG 1 2 0 0 8 N
1048 ANSEDSGX 1 2 0 0 8 Y
1049 ANSETSG 1 3 0 0 8 N
1050 ANDEDSG 2 2 0 0 8 N
1051 ANSEDSGI 1 2 1 0 8 N
1052 ANSETSGX 1 3 0 0 8 Y
1053 ANDEDSGX 2 2 0 0 8 Y
1054 ANSEDSGIX 1 2 1 0 8 Y
1055 ANSEDSX 1 2 0 0 0 Y
1056 ANSETSX 1 3 0 0 0 Y
1057 ANDEDSX 2 2 0 0 0 Y
1058 ANSEDSTX 1 2 0 1 0 Y
1059 ANSETSTX 1 3 0 1 0 Y
1060 ANDEDSTX 2 2 0 1 0 Y
1061 ANDSTI2X 0 2 1 0 0 Y
1062 ANSEDSI2X 1 2 1 0 0 Y
1063 ANSEDSTI2X 1 2 1 1 0 Y
4096 ATMALC 0 0 0 0 0 0
4097 ATMALCTAXI100 0 0 0 0 0 1
4098 ATMALCSONETMM 0 0 0 0 1 1 [9]
4099 ATMALCSONETSM 0 0 0 0 1 1 [9]
4352 OSYNC 0 8 0 0 0 0
4353 OSYNC_COMP (32) 0 8 0 0 0 0
4354 OSYNC_COMP128 0 8 0 0 0 0
4608 ATMCOC3MM 0 0 0 0 1 1 [10]
4609 ATMCOC3SM 0 0 0 0 1 1 [10]
4610 ATMCOC3UTP5 0 0 0 0 1 0 [10]
4864 DE100 2 0 0 0 0 0
5120 ATMCDS3 0 0 0 0 1 0 [10]
5121 ATMCE3 0 0 0 0 1 0 [10]
8448 SRML 0 0 0 0 0 0
NOTES:
[1] Indicates Module has COM Port 1 configured for ASYNC.
The AM8530's port B is configured for COM1.
[2] This Module contains the DEFA - Hardware Filtering. CAMS
must be programmed (can contain 2 - 6 CAMS onboard).
[3] The AM8530 has been removed (depopulated) from this module.
Programming this device should not be performed.
[4] Contains Dual Defa hardware. (Can be depopulated)
[5] Depop'd two ports of hardware to make Dual Ethernet module.
[6] These are FDDI modules. The ID cannot be read from the Link
module I/O space.
[7] These are AFN Platform Integrated 'Modules' - Cannot be detached
or be used by any other platform.
[8] Module IDs from 1280(0x500) to 2559(0x9ff) are used
for the ASN Net Modules. Module ID 512(0x200) is
used for the ASN SPEX. These IDs are documented in
module.mib. A module ID of 511(0x1ff) in
'wfHwEntry.wfHwModIdOpt' indicates that it is an
ASN platform and the user should refer to
'wfHwModuleEntry.wfHwModuleModIdOpt' for Module ID details.
[9] ATMALC link modules. The physical option for SONET includes a
framer and the medium is fiber optics. Only one port per physical
daughtercard per link module.
[10] ARE UTOPIA link modules.
[11] Module IDs from 8704(0x2200) to 16383(0x3FFF) are used
for the ARN Net Modules. These IDs are documented in
module.mib. A module ID of 767(0x2ff) in
'wfHwEntry.wfHwModIdOpt' indicates that it is a
Neptune platform and the user should refer to
'wfHwModuleEntry.wfHwModuleModIdOpt' for Module ID details.
[12] Module IDs from 16384(0x4000) to 18944(0x4A00) are used
for the SN Switched Net Modules (SNM). These IDs are documented
in module.mib. A module ID of 513(0x201) in
'wfHwEntry.wfHwModIdOpt' indicates that it is an
SN (Fiddlestix) platform and the user should refer to
'wfHwModuleEntry.wfHwModuleModIdOpt' for Module ID details.
[13] A module ID of 777(0x309) in 'wfHwEntry.wfHwModIdOpt' indicates
that it is a FBR (Fast Branch Router) platform and the user should
refer to 'wfHwModuleEntry.wfHwModuleModIdOpt' for Module ID details.
[14] A module ID of 778(0x30A) in 'wfHwEntry.wfHwModIdOpt' indicates
the presence of a PCI PMC carrier card. The carrier card can have
2 PMC cards attached to it. For PMC card module IDs, refer to
'wfHwModuleEntry.wfHwModuleModIdOpt' for details.Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.18.3.1.2.1.2 snmpwalk -v2c -c public <target> Wellfleet-HARDWARE-MIB::wfHwModIdOpt
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.18.3.1.2.1.2.1 snmpget -v2c -c public <target> Wellfleet-HARDWARE-MIB::wfHwModIdOpt.1
Start monitoring Legacy Wellfleet Communications (Bay Networks/Nortel) routers (backplane/power-supply/fan/temperature status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Wellfleet-HARDWARE-MIB::wfHwModIdOpt OID value, configure state conditions and alerts, and monitor any Legacy Wellfleet Communications (Bay Networks/Nortel) routers (backplane/power-supply/fan/temperature status) from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.18 | wellfleet | Wellfleet-COMMON-MIB |
| 1.3.6.1.4.1.18.3 | wfSwSeries7 | Wellfleet-COMMON-MIB |
| 1.3.6.1.4.1.18.3.1 | wfHardwareConfig | Wellfleet-COMMON-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.18.3.1.2 | wfHwTable | Wellfleet-HARDWARE-MIB |
| 1.3.6.1.4.1.18.3.1.2.1 | wfHwEntry | Wellfleet-HARDWARE-MIB |
| 1.3.6.1.4.1.18.3.1.2.1.2 | wfHwModIdOpt | Wellfleet-HARDWARE-MIB |