WWP-OAM-MIB :: wwpOamPeerConfigRevision

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsWWP-OAM-MIBwwpOamPeerConfigRevision

wwpOamPeerConfigRevision

Module: WWP-OAM-MIB

OID (symbolic): WWP-OAM-MIB::wwpOamPeerConfigRevision

OID (numeric): 1.3.6.1.4.1.6141.2.400.1.2.2.1.7

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-only

Description: The configuration revision of the OAM peer as reflected in the latest OAMPDU. This attribute is changed by the peer whenever it has a local configuration change for Ethernet OAM this interface. This value is initialized to all zeros (0x00000000), and is invalid if the wwpOamPeerStatus is inactive.

The configuration revision can be determined from the Revision

field of the Local Information TLV of the most recently received Information OAMPDU with a Local Information TLV.

An Information OAMPDU is indicated by a valid frame with (1) destination MAC address equal to that of the reserved MAC address for Slow Protocols (See 43B of [802.3ah]), (2) a lengthOrType field equal to the reserved type for Slow Protocols, (3) a Slow Protocols subtype equal to that of the subtype reserved for OAM, and (4) a OAM code that equals the code reserved for Information OAMPDUs.

What is wwpOamPeerConfigRevision?

This OID reports the configuration revision number currently being advertised by the OAM peer, which the peer increments whenever it has a local OAM-relevant configuration change. An admin watches this value to detect that the far-end device has changed its OAM configuration.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6141.2.400.1.2.2.1.7
snmpwalk -v2c -c public <target> WWP-OAM-MIB::wwpOamPeerConfigRevision

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.6141.2.400.1.2.2.1.7.1
snmpget -v2c -c public <target> WWP-OAM-MIB::wwpOamPeerConfigRevision.1

Start monitoring World Wide Packets / Ciena LEOS Ethernet access device, IEEE 802.3ah-compliant Ethernet equipment (link-fault/OAM-peer-discovery status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WWP-OAM-MIB::wwpOamPeerConfigRevision OID value, configure state conditions and alerts, and monitor any World Wide Packets / Ciena LEOS Ethernet access device, IEEE 802.3ah-compliant Ethernet equipment (link-fault/OAM-peer-discovery status) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6141wwpWWP-SMI
1.3.6.1.4.1.6141.2wwpModulesWWP-SMI
Numeric OIDNameModule
1.3.6.1.4.1.6141.2.400wwpOamMibModuleWWP-OAM-MIB
1.3.6.1.4.1.6141.2.400.1wwpOamMIBWWP-OAM-MIB
1.3.6.1.4.1.6141.2.400.1.2wwpOamObjsWWP-OAM-MIB
1.3.6.1.4.1.6141.2.400.1.2.2wwpOamPeerTableWWP-OAM-MIB
1.3.6.1.4.1.6141.2.400.1.2.2.1wwpOamPeerEntryWWP-OAM-MIB
1.3.6.1.4.1.6141.2.400.1.2.2.1.7wwpOamPeerConfigRevisionWWP-OAM-MIB