WWP-OAM-MIB :: wwpOamLoopbackControlTx

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsWWP-OAM-MIBwwpOamLoopbackControlTx

wwpOamLoopbackControlTx

Module: WWP-OAM-MIB

OID (symbolic): WWP-OAM-MIB::wwpOamLoopbackControlTx

OID (numeric): 1.3.6.1.4.1.6141.2.400.1.2.4.1.5

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: A count of the number of Loopback Control OAMPDUs transmitted on this interface.

An Loopback Conrol OAMPDU is indicated by a valid frame with (1) destination MAC address equal to that of the reserved MAC address for Slow Protocols (See 43B of [802.3ah]), (2) a lengthOrType field equal to the reserved type for Slow Protocols, (3) a Slow Protocols subtype equal to that of the subtype reserved for OAM, and (4) an OAMPDU code equals the OAM Loopback Control code.

Discontinuities of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of the ifCounterDiscontinuityTime.

What is wwpOamLoopbackControlTx?

This OID counts Loopback Control OAMPDUs transmitted on this interface, the messages used to start or stop a remote loopback test. An admin checks this to confirm a loopback command issued via wwpOamLoopbackCommand actually resulted in a control OAMPDU going out.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6141.2.400.1.2.4.1.5
snmpwalk -v2c -c public <target> WWP-OAM-MIB::wwpOamLoopbackControlTx

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.6141.2.400.1.2.4.1.5.1
snmpget -v2c -c public <target> WWP-OAM-MIB::wwpOamLoopbackControlTx.1

Start monitoring World Wide Packets / Ciena LEOS Ethernet access device, IEEE 802.3ah-compliant Ethernet equipment (link-fault/OAM-peer-discovery status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WWP-OAM-MIB::wwpOamLoopbackControlTx OID value, configure state conditions and alerts, and monitor any World Wide Packets / Ciena LEOS Ethernet access device, IEEE 802.3ah-compliant Ethernet equipment (link-fault/OAM-peer-discovery status) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6141wwpWWP-SMI
1.3.6.1.4.1.6141.2wwpModulesWWP-SMI
Numeric OIDNameModule
1.3.6.1.4.1.6141.2.400wwpOamMibModuleWWP-OAM-MIB
1.3.6.1.4.1.6141.2.400.1wwpOamMIBWWP-OAM-MIB
1.3.6.1.4.1.6141.2.400.1.2wwpOamObjsWWP-OAM-MIB
1.3.6.1.4.1.6141.2.400.1.2.4wwpOamStatsTableWWP-OAM-MIB
1.3.6.1.4.1.6141.2.400.1.2.4.1wwpOamStatsEntryWWP-OAM-MIB
1.3.6.1.4.1.6141.2.400.1.2.4.1.5wwpOamLoopbackControlTxWWP-OAM-MIB