WWP-LEOS-FLOW-MIB :: wwpLeosFlowServiceRedCurveUnset

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › WWP-LEOS-FLOW-MIB › wwpLeosFlowServiceRedCurveUnset

wwpLeosFlowServiceRedCurveUnset

Module: WWP-LEOS-FLOW-MIB

OID (symbolic): WWP-LEOS-FLOW-MIB::wwpLeosFlowServiceRedCurveUnset

OID (numeric): 1.3.6.1.4.1.6141.2.60.6.1.1.24.1.7

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-write

Description: Setting this object to true will reset the red curve settings to factory defaults.

What is wwpLeosFlowServiceRedCurveUnset?

Set to true to reset just this one RED curve's thresholds and drop probability back to factory defaults, without affecting any other curves in the table.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6141.2.60.6.1.1.24.1.7
snmpwalk -v2c -c public <target> WWP-LEOS-FLOW-MIB::wwpLeosFlowServiceRedCurveUnset

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.6141.2.60.6.1.1.24.1.7.1
snmpget -v2c -c public <target> WWP-LEOS-FLOW-MIB::wwpLeosFlowServiceRedCurveUnset.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.6141.2.60.6.1.1.24.1.7.1 s <value>

Start monitoring Ciena (World Wide Packets) LEOS-based carrier Ethernet access/aggregation switches (MAC-motion event/CPU-rate-limit status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WWP-LEOS-FLOW-MIB::wwpLeosFlowServiceRedCurveUnset OID value, configure state conditions and alerts, and monitor any Ciena (World Wide Packets) LEOS-based carrier Ethernet access/aggregation switches (MAC-motion event/CPU-rate-limit status) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6141wwpWWP-SMI
1.3.6.1.4.1.6141.2wwpModulesWWP-SMI
1.3.6.1.4.1.6141.2.60wwpModulesLeosWWP-SMI
Numeric OIDNameModule
1.3.6.1.4.1.6141.2.60.6wwpLeosFlowMIBWWP-LEOS-FLOW-MIB
1.3.6.1.4.1.6141.2.60.6.1wwpLeosFlowMIBObjectsWWP-LEOS-FLOW-MIB
1.3.6.1.4.1.6141.2.60.6.1.1wwpLeosFlowWWP-LEOS-FLOW-MIB
1.3.6.1.4.1.6141.2.60.6.1.1.24wwpLeosFlowServiceRedCurveTableWWP-LEOS-FLOW-MIB
1.3.6.1.4.1.6141.2.60.6.1.1.24.1wwpLeosFlowServiceRedCurveEntryWWP-LEOS-FLOW-MIB
1.3.6.1.4.1.6141.2.60.6.1.1.24.1.7wwpLeosFlowServiceRedCurveUnsetWWP-LEOS-FLOW-MIB