All MIBs › WISI-GTSETTINGS-MIB › gtUpdateControl
gtUpdateControl
Module: WISI-GTSETTINGS-MIB
OID (symbolic): WISI-GTSETTINGS-MIB::gtUpdateControl
OID (numeric): 1.3.6.1.4.1.7465.20.2.9.1.5.1.10.1
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: The gtUpdateControl controls the module update process. The gtUpdateControl can be set to the following values:
downloadFirmware(1) - download the firmware, entitlement or private key file given by gtFirmwareFilename from the SFTP server. There can be only one firmware per module type stored at a time, only one entitlement file per module and only one single private key. If you download a new firmware file for a type that already exists on the rack unit, the old firmware is deleted. Firmware file names must start with the module type, e.g., 'GT11_firmware_vXX.bin' or 'gt22-firmware.bin'. Entitlement files must have a file name of 'xxxxxxxxxxxxxxxx.ent', where xxxxxxxxxxxxxxxx is the serial number of the target module, as a 16 digit hexadecimal number. Private key file names must end in '.ppk'.
updateModules(2) - update all modules in the chassis with the firmware previously downloaded, corresponding to their module types.
updateSwitch(3) - update the GT11 with the firmware downloaded previously.
deleteAllFirmwareFiles(4) - delete all previously stored firmware and entitlement files.
deletePrivateKey(5) - delete the stored private key.
updateEntitlements(6) - update all modules and the GT11 using the entitlement files with their respective IDs that were previously downloaded.
What is gtUpdateControl?
This read-write value issues a firmware-update-related command such as downloading firmware/entitlement/private-key files, updating all modules, updating the switch itself, deleting stored firmware files, or updating module entitlements. An admin uses updateModules(2) after downloadFirmware(1) to actually roll the new firmware out to every module in the chassis.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.7465.20.2.9.1.5.1.10.1 snmpwalk -v2c -c public <target> WISI-GTSETTINGS-MIB::gtUpdateControl
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.7465.20.2.9.1.5.1.10.1.1 snmpget -v2c -c public <target> WISI-GTSETTINGS-MIB::gtUpdateControl.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.7465.20.2.9.1.5.1.10.1.1 i <value>
Start monitoring WISI Communications next-generation cable headend systems (license-expiry/IGMP-snooping/VLAN config status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the WISI-GTSETTINGS-MIB::gtUpdateControl OID value, configure state conditions and alerts, and monitor any WISI Communications next-generation cable headend systems (license-expiry/IGMP-snooping/VLAN config status) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.7465 | wisi | WISI-ROOT-MIB |
| 1.3.6.1.4.1.7465.20 | equipment | WISI-ROOT-MIB |
| 1.3.6.1.4.1.7465.20.2 | devices | WISI-ROOT-MIB |
| 1.3.6.1.4.1.7465.20.2.9 | tangram | WISI-ROOT-MIB |
| 1.3.6.1.4.1.7465.20.2.9.1 | gtUnit | WISI-TANGRAM-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.7465.20.2.9.1.5 | gtSettingsMIB | WISI-GTSETTINGS-MIB |
| 1.3.6.1.4.1.7465.20.2.9.1.5.1 | gtSettingsObjects | WISI-GTSETTINGS-MIB |
| 1.3.6.1.4.1.7465.20.2.9.1.5.1.10 | gtModuleUpdate | WISI-GTSETTINGS-MIB |